2 GP Editor Data Download
© Copyright Reserved Autonics Co., Ltd. 45
2.2.2 GP, LP configuration
This chaper is described by each of RS422/RS232C serial interface type.
For more details, refer to ‘GP Editor user manual’.
2.2.2.1 Mono type
1st Enter system setting menu.
Touch left-upper point as default position of system setting menu.
2nd Select [SET ENVIRONMENT]-[PLC SETTING].
3rd CH2 protocol is set as ‘EDITOR’ and CH2 connection port is set as ‘RS232C’ as
default. (For donwloading drawn data of GP Editor to GP/LP, use ‘RS232C’ port. In
case of using RS232/422 converter, you can download it with RS422 port.)
4th If it is not configured as ‘EDITOR’ for CH2 protocol, touch protocol display item to set
‘EDITOR’ as following figure.
Protocol display rotates in order as No Use→EDITOR→PRINTER→BARCODE→
MONITOR with touching.