User manual
1 Product Overview
© Copyright Reserved Autonics Co., Ltd. 29
No
Link Device
Description
⑦
CH2 Inner Link
Device
Designate lead word address of GP/LP for communication with CH2.
⑧
Link Device Setting
Status
Displays bit/word, channel, station, start device, count, read/write of
CH1/CH2 to communicate with GP/LP
⑨
Add
Adds link device settings. ‘Link Device’ dialog box appears.
ⓐBit/Word: Select bit/word device of PLC to communicate
ⓑStart Device: Designate start device of PLC to communicate
ⓒStart Device: Displays selected channel at ⓑ
ⓓStart Device: Displays selected device at ⓑ
ⓔNumbers: Designate the number of read/write device from start
device at ⓑ
ⓕRead/Write: Set read/write operation for designated device
※For mono type, link device information by each channel is able to
register up to 5.
※For color type, link device information by each channel is able to
register to infinity.
⑩
Edit
Edit the selected item on ⑧ among set link device
⑪
Delete
Delete the selected item on ⑧ among set link device
⑫
Delete All Delete all of set link device
⑬
UP Moves up all items of set link device.
⑭
DOWN Moves down all items of set link device.