User manual

6 Connectable PLC
252 © Copyright Reserved Autonics Co., Ltd.
Command value
(DEC)
Command
description
Executing operation Note
00513 Target value 1
00514
Target value 2
00515 Target value 3
00768
AT
Stops AT
00769 Executes AT
Available when it
is STOP
01024
Write mode
Backup write mode
01025 Write mode RAM
01280 Preserves RAM DATA Preserves RAM DATA
01536 Soft reset Soft reset
01792 Executes setting area 1 Executes setting area 1
02048 Executes protect level Executes protect level
02304
AUTO/ MANUAL
AUTO mode
02305 MANUAL mode
02816
Initializes setting value
Initial default of setting value
02817 Initial setting service value
04352
Starts program
Start reset program
04353 Starts program
6.13.4 Monitorable device in GP/LP
GP/LP is able to monitor PLC device and change the status.
Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select
to be monitored device and you can change the status.
The following is avilable device list of this menu, and available range is same as 6.11.3
Available device’.
Type Mark Device Note
Bit UB
GP/LP inner bit
memory
Word
M
Operation command
device
DM16 Variable Device 16bit
DM32 Variable Device
32bit type combining designated number of
device and next number of device
UW
GP/LP inner word
memory