User manual
1 Product Overview
24 © Copyright Reserved Autonics Co., Ltd.
(1) In case of using only CH1 configured in GP Editor
No Item Operation with touching
①
Displays CH1 protocol
Rotates in order as downloaded protocol in GP Editor →
EDITOR → PRINTER → BARCODE → UNIVERSAL
→ DEFAULT protocol
②
Displays CH1 connect port
(Designates automatically
as non-using port in ④)
Each of RS422 / RS232C interface type:
RS422 PORT ↔ RS232C PORT
Two ports of RS232C interface type:
RS232C A PORT ↔
RS232C B PORT
③
Displays CH2 protocol
(as EDITOR for default)
Rotates in order as EDITOR → PRINTER → BARCODE
→ MONITOR → UNIVERSAL → No Use
④
Displays CH2 connect port
(Designates automatically
as non-using port in ②)
Each of RS422 / RS232C interface type:
RS422 PORT ↔ RS232C PORT
Two ports of RS232C interface type:
RS232C A PORT ↔
RS232C B PORT
⑤⑥
Communication
configuration by each
channel
Moves communication configuration setting window for
selected connected device.
You can designate baudrate, data bit, parity, stop bit, and
flow control for each channel.
If CH1 is as NoUse, it is not able to communication
configuration.