6 Connectable PLC
© Copyright Reserved Autonics Co., Ltd. 195
6.7.1.2 When using Cnet Unit,
PLC type
Unit model
name
Communication
method
Baudrate (bps)
LS Master-K
MK-80S
G7L-CUEB RS232C
19200
G7L-CUEC RS422
MK-120S
G7L-CUEB RS232C
G7L-CUEC RS422
MK-200S
G6L-CUEB RS232C
G6L-CUEC RS422
MK-300S G4L-CUEA RS232C, RS422
MK-1000S G3L-CUEA RS232C, RS422
In case of K7M-DR10S CPU of MK-80S, Cnet Unit cannot be connetable.
(1) Cnet Unit RS-232C(Applied cable (6)C3M5P05-D9F0-D9M0)
(2) Cnet Unit RS-422(Applied cable (16)C3M5P04-D9M0-T6Y0)
6.7.2 Communication configuration
6.7.2.1 Communication configuration when using embedded Cnet CPU
Communication configuration for using embedded Cnet CPU is set from the dedicated ladder
program (KGL for Window) and communication configuration method is as following.
1st Connect the dedicated ladder program and set PLC as connectable status.
2nd From the workspace window of the ladder program, select [Parameter] and desigante
the items as below.
Item Setting Note
Station User-defined 0 to 31(Current station is only 0)
Stop bit 1 Fixed
Data bit 8 Fixed
Parity None Fixed
Baudrate 19200 Fixed