User manual
5 Universal (General-purpose communication)
© Copyright Reserved Autonics Co., Ltd. 117
5 Universal (General-purpose communication)
Universal indicates general purpose of communication, Modbus Slave communication is
supported in GP/LP.
5.1 System organization
Microcomputer using as host unit is able to execute slave communicate with GP/LP through RS-
232C or RS-422(RS-485) communication port. Host unit read and write inner register(UB, UW)
of GP/LP as communication commander. Host unit as master transmits command to GP/LP and
GP/LP as slave executes designated operation according to transmitted command and sends
respond message.
The following is the system organization for connecting with GP/LP and host unit.
※For connect cable information, refer to ‘1.3 Communication’.
The following table is for basic communication configuration of host unit.
No
Item
Description
Note
1
Communication
mode
RTU Not used
2 Baudrate 38400 bps Fixed
3 Data type
Data length 8 bit Fixed
Parity None Fixed
Stop bit 1 bit Fixed
4 Station 1 to 31 Designate this in GP/LP