USER MANUAL For COMMUNICATION © Copyright Reserved Autonics Co., Ltd.
iv © Copyright Reserved Autonics Co., Ltd.
Preface Preface Thank you very much for selecting Autonics products. Please familiarize yourself with the information contained in the Safety Precautions section before using this product. This user manual contains information about the product and its proper use, and should be kept in a place where it will be easy to access. © Copyright Reserved Autonics Co., Ltd.
User Manual Guide User Manual Guide iv Please familiarize yourself with the information in this manual before using the product. This manual provides detailed information on the product's features. It does not offer any guarantee concerning matters beyond the scope of this manual. This manual may not be edited or reproduced in either part or whole without permission. A user manual is not provided as part of the product package. Please visit our home-page (www.autonics.
User Manual Symbols User Manual Symbols Symbol Description Supplementary information for a particular feature. Failure to follow instructions can result in serious injury or death. Failure to follow instructions can lead to a minor injury or product damage. An example of the concerned feature's use. ※1 Annotation mark. © Copyright Reserved Autonics Co., Ltd.
Safety Precautions Safety Precautions Following these safety precautions will ensure the safe and proper use of the product and help prevent accidents and minimize hazards. Safety precautions are categorized as Warnings and Cautions, as defined below: Warning Caution vi Cases that may cause serious injury or fatal accident if instructions are not followed. Cases that may cause minor injury or product damage if instructions are not followed.
Safety Precautions cause malfunction and output error. It may cause a fire, human injury or property loss. Do not use the product in an area or an environment not specified in the manual. It may cause a fire, human injury or property loss. Do not connect, inspect or repair when power is on. It may cause a fire or give an electric shock. Do not disassemble the product. Please contact us if it is required. It may cause a fire or give an electric shock.
Safety Precautions When liquid crystal from the broken LCD is smeared with skin, wash it for 15 minutes. If it is gotten in the eye, wash it for 15 minutes and contact with the medical specialist for more information. In cleaning unit, do not use water or an oil-based detergent and use dry towels. It may cause an electric shock or a fire. Please separate as an industrial waste when disuse this unit. To change the battery, contact the store or an authorized technician.
Safety Precautions © Copyright Reserved Autonics Co., Ltd.
Table of Contents Table of Contents Preface .............................................................................................................................iii User Manual Guide ......................................................................................................... iv User Manual Symbols ...................................................................................................... v Safety Precautions ...................................................................
Table of Contents 3.6 System signal .................................................................................................. 103 3.6.1 3.6.2 3.6.3 3.6.4 4 5 4.1 Ordering information ........................................................................................ 107 4.2 Cable wiring and dimensions........................................................................... 107 4.3 Communication cable by connectable device .................................................
Table of Contents 6.5 LS XGB Series PLC communication connection ............................................ 181 6.5.1 6.5.2 6.5.3 6.5.4 6.6 LS XGT Series PLC communication connection ............................................. 188 6.6.1 6.6.2 6.6.3 6.6.4 6.7 System organization ................................................................................. 208 Available device ....................................................................................... 210 Monitorable device in GP/LP.
Table of Contents 6.15.1 System organization ................................................................................. 261 6.15.2 Available device ....................................................................................... 262 6.15.3 Monitorable device in GP/LP .................................................................... 265 6.16 KONICS Product connection ........................................................................... 266 6.16.1 System organization ................
1 Product Overview 1 Product Overview GP and LP series which is connected with various controllers including PLC, temperature controller displays and monitors the operation of control variable by LCD screen visually as grahpic interface device. You can switch the screen and set or edit the variable value by touching LCD screen. The variable value with various data type is displayed by graphic object(tag) drawn from GP Editor which is dedicated software for GP, LP screen.
1 Product Overview 1.2 System organization GP, LP is able to communicate with various controllers including PLC, multi meter, pulse meter, temperature & humidity sensor and temperature controller. GP,LP and controllers can execute RS-232C/RS-422(RS-485) communication, and please refer to the each controller section for more information about module or adapter to convert communication. The following is the system organization for connecting with GP, LP. ※1. Printer supports serial communication.
1 Product Overview The below is computer specification requried to use software. Operating system: Windows98/NT/XP Item Minimum specifications Recommended specification CPU Pentium 4 or above Pentium Dual Core Memory 512 MB 1GB Hard disk 1 GB (Free space) 5GB (Free space) Resolution 1024 × 768 1280 × 1024 1.3 Communication 1.3.1 RS232C (1) Transmission standard No.
1 Product Overview 1.3.2 RS422 (1) Transmission standard No. Item Description 1 Communication method Full Duplex 2 Synchronous method Asynchronous 3 Communication distance Approx.
1 Product Overview 1.3.3 Mono type This menu displays connected device to RS232C, RS422 port of GP/LP. You can designate station and connected port by each channel. No Function Operation Displays connected device and connect port for CH1. ① CH1 Touch this to select one from downloaded protocol in GP Editor, EDITOR, configuration PRINTER, BARCODE, UNIVERSAL, or DEFAULT protocol (MK- line 200S(CPU)) and designate connect port. (Select between RS232C/RS422 or RS232C-A / RS232C-B).
1 Product Overview (1) In case of using only CH1 configured in GP Editor No Item Operation with touching Rotates in order as downloaded protocol in GP Editor ① Displays CH1 protocol → EDITOR → PRINTER → BARCODE → UNIVERSAL → DEFAULT protocol (MK-200S(CPU)) Displays CH1 connect port ② (Designates automatically as non-using port in ④) ③ Two ports of RS232C interface type: RS232C A PORT ↔ RS232C B PORT Rotates in order as No Use → EDITOR → PRINTER (as EDITOR for default) → BARCODE (Designates aut
1 Product Overview (2) In case of using only CH2 configured in GP Editor No Item ① Displays CH1 protocol Operation with touching Rotates in order as NoUse → EDITOR → Displays CH1 connect port ② (Designates automatically as non-using port in ④) Displays CH2 protocol ③ (as downloaded protocol for default) Displays CH2 connect port ④ (Designates automatically as non-using port in ②) ⑤⑥ Communication configuration by each channel © Copyright Reserved Autonics Co., Ltd.
1 Product Overview (3) CH1/ CH2 details configuration No Function and operation ① Designate the device to be connected for CH1, CH2. CH1, CH2 protocol: Communication mode for set PLC by GP and GP Editor by each port. EDITOR: I/O mode for downloading user-designed or PLC programming data from GP Editor or SmartStudio. PRINTER: Print mode for printing alarm history of GP. Refer to ‘3.5.3 PRINTER communication configuration’. BARCODE: Input mode for reading data from barcode. Refer to ‘3.5.
1 Product Overview 1.3.4 Color type This menu displays connected device to RS232C, RS422 port of GP/LP. You can designate station and connected port by each channel. No ① ② Function CH1 configuration CH2 configuration GP station ③ configuration touch key Operation Displays connected device and connect port for CH1. Touch this to select one from downloaded protocol in GP Editor, EDITOR, PRINTER, BARCODE, UNIVERSAL, or DEFAULT protocol and designate connect port.
1 Product Overview (1) In case of using only CH1 configured in GP Editor No Item Operation with touching Rotates in order as downloaded protocol in GP Editor → ① Displays CH1 protocol EDITOR → PRINTER → BARCODE → UNIVERSAL → DEFAULT protocol Displays CH1 connect port ② (Designates automatically as non-using port in ④) ③ RS232C A PORT ↔ RS232C B PORT (as EDITOR for default) → MONITOR → UNIVERSAL → No Use (Designates automatically Communication configuration by each channel 24 Two ports of RS
1 Product Overview (2) In case of using only CH2 configured in GP Editor No Item ① Displays CH1 protocol Operation with touching Rotates in order as NoUse → EDITOR → Displays CH1 connect port ② (Designates automatically as non-using port in ④) Displays CH2 protocol ③ (as downloaded protocol for default) Displays CH2 connect port ④ (Designates automatically as non-using port in ②) ⑤⑥ Communication configuration by each channel © Copyright Reserved Autonics Co., Ltd.
1 Product Overview (3) CH1/ CH2 details configuration 26 No Function and operation ① Designate the device to be connected for CH1, CH2. CH1, CH2 protocol: Communication mode for set PLC by GP and GP Editor by each port. EDITOR: I/O mode for downloading user-designed data from GP Editor PRINTER: Print mode for printing alarm history of GP Refer to ‘3.5.3 PRINTER communication configuration’. BARCODE: Input mode for reading data from barcode Refer to ‘3.5.
1 Product Overview No Function and operation ② Touch this, detailed configuration screen for designated operation mode appears. ③ to ⑦ Designate detailed configuration for designated operation mode. Baudrate: Designate baud rate. Supports 300/600/1200/2400/4800/9600/19200/38400/57600/115200bps Data: Designate data bit. Supports 7 bit, or 8 bit. Stop bit: Designate stop bit. Supports 1 bit, or 2 bit. Parity: Designate parity type. Supports even, odd, or none parity.
1 Product Overview 1.4 Link device Generally GP/LP monitors directly PLC device of CH1. To link PLC device of CH1 and GP/LP connect device (by saving monitored PLC device value to specified GP/LP connect device), link devie menu is needed. Mono type must use link device with CH2 to communicate 1:N. Color type is able to monitor directly PLC device of each channel (CH1,CH2). Therefore, color type does not use link device and is able to communicate 1:N without CH1, CH2 division.
1 Product Overview No ⑦ ⑧ Link Device CH2 Inner Link Device Description Link Device Setting Status Displays bit/word, channel, station, start device, count, read/write of CH1/CH2 to communicate with GP/LP Designate lead word address of GP/LP for communication with CH2. Adds link device settings. ‘Link Device’ dialog box appears.
1 Product Overview No Link Device ⑬ Linked Status Description Displays table for link device setting of set between GP/LP and CH1, GP/LP and CH2. Communication direction GP/LP CH1 station CH1 PLC GP/LP series ※1 UW200 to UW209 - (Write) → D100 to D109 UW210 to UW219 - (Write) → D110 to D119 UW220 to UW229 - (Write) → D120 to D129 UW230 to UW234 - (Read) ← D130 to D134 UW235 to UW239 - (Read) ← D135 to D139 MK-200S ※1.
1 Product Overview GP/LP CH2 station Communication direction GP/LP series ※1 UW300 to UW309 - (Read) ← D0 to D9 UW310 to UW319 - (Read) ← D10 to D19 UW320 to UW329 - (Read) ← D20 to D29 UW330 to UW334 - (Write) → D30 to D34 UW335 to UW339 - (Write) → D35 to D39 CH2 PLC FX-2N ※1. Mono type(GP-S044, GP-S057, LP-S044) ) is able to communicate 1:1, 1:N for CH2 and supports multi station selection.
1 Product Overview (2) CH1 inner link device: UW (i) Link device setting Start Device: D1(i), Bit/Word: Word, Numbers: A, Read/Write: Write Start Device: D2(i), Bit/Word: Bit, Numbers: B, Read/Write: Read Start Device: D3(i), Bit/Word: Word, Numbers: C, Read/Write: Read Start Device: D4(i), Bit/Word: Bit, Numbers: D, Read/Write: Read Start Device: D5(i), Bit/Word: Word, Numbers: E, Read/Write: Write Inner link device (Word) Communication direction CH1 First A units of device from UW (i
1 Product Overview CH1 GP connect device: UW(30) Link device setting Start Device: K(0), Bit/Word: Word, Numbers: 5, Read/Write: Write Start Device: M(0), Bit/Word: Word, Numbers: 3, Read/Write: Read Start Device: P(10), Bit/Word: Bit, Numbers: 20, Read/Write: Read Device: D(10), Bit/Word: Word, Numbers: 6, Read/Write: Write GP/LP Inner link device (Word) UW(30) to UW(34) CH1 Numbers Communicat ion direction Device Numbers 5 (Write) → K(0) to K(4) Word 5 UW(35) to UW(37) 3
1 Product Overview (3) Station N Start Device: N_D1(i), Bit/Word: Word, Numbers: AN Start Device: N-D2(i), Bit/Word: Word, Numbers: BN Start Device: N-D3(i), Bit/Word: Word, Numbers: CN Start Device: N-D4(i), Bit/Word: Word, Numbers: DN Start Device: N-D5(i), Bit/Word: Word, Numbers: EN Inner link device (Word) Communic ation direction First A0 units of device from D(i) Read/Write 0_D1(i) to 0_D1(i+A0-1) B0 units of device from the next Read/Write 0_D2(i) to 0_D2(i+B0-1) C0 units
1 Product Overview (4) Station 1 Start Device: K(0), Bit/Word: Word, Numbers:5, Read/Write: Write Start Device: M(0), Bit/Word: Bit, Numbers:3, Read/Write: Write Start Device: D(0), Bit/Word: Word, Numbers:4, Read/Write: Read Start Device: D(10), Bit/Word: Word, Numbers:6, Read/Write: Write (5) Station 3 Start Device: K(10), Bit/Word: Bit, Numbers:2, Read/Write: Read Start Device: M(16), Bit/Word: Word, Numbers:5, Read/Write: Write (6) Station 11 Start Device: D(20), Bit/Word: Word, N
1 Product Overview 1.5 Connectable device Connectable PLC with GP, LP is constantly being update. Connectable Communication device connection type GP-2480 (Below V2.70) GP-2480 (Above V3.
1 Product Overview Series MITSUBISHI Q(with Cnet Unit) NAIS FP SIEMENS SIMATIC S7-200 SIEMENS SIMATIC S7-300 Connectable Communication device connection type GP-2480 (Below V2.70) GP-2480 (Above V3.
1 Product Overview Series Allen-Bradley OMRON SYSMAC C OMRON temperature controller Connectable Communication device connection type GP-2480 (Below V2.70) GP-2480 (Above V3.
1 Product Overview Series GP-2480 (Below V2.70) GP-2480 (Above V3.00) GP-S057 GP/LPS044 GP/LPS070 Modbus(TYPE A)※1 × × ○ ○ ○ Connectable Communication device connection type UNIVERSAL UNIVERSAL Modbus(Slave) ○ ○ ○ ○ ○ MODBUS MASTER MODBUS MASTER Modbus(Master)※1 × × ○ ○ ○ ※1. Modbus(TYPE A) supports every GP/LP series except GP-2480 series. 1.
1 Product Overview 40 © Copyright Reserved Autonics Co., Ltd.
2 GP Editor Data Download 2 GP Editor Data Download You can download created data from GP Editor which is drawing software in PC to GP, LP. 2.1 System organization GP, LP are basically supported by RS-232C communication and RS-422 communication is also available only with RS232/422 converter. It is required to use dedicated transmitting cable(sold separately) to transmit the data. You can create the cable, refer to below. The below is a diagram and pin arrangement for RS-232C cable to transmit data.
2 GP Editor Data Download 2.2 Communication configuration There are two configurations to transmitting data. First is GP Editor configuration, and second is GP, LP configuration. 2.2.1 GP Editor configuration This manual describes basic communication configuraion of GP Editor and serial communication. For more details, refer to ‘GP Editor user manual’. Through GP Editor which is dedicated drawn software, you can download the data to GP/LP.
2 GP Editor Data Download 4th ‘Project Auxiliary Property’ dialog box appears. Designate the desired setting and click ‘OK’. 5th Draw the data to download for GP/LP. For further details of drawing, refer to ‘GP Editor user manual’. 6th After completing data input, select [Communication]-[Download] of menu. ‘Monitor Data Download’ dialog box appears. 7th Click ① ‘Setting’ button and ‘Option’ dialog box appears. © Copyright Reserved Autonics Co., Ltd.
2 GP Editor Data Download 8th Designate the connected communication port of PC to GP/LP and synchronize baud rate between GP/LP and GP Editor. Click ‘OK’. Baudrate default is 115200 bps at GP/LP and GP Editor. 9th Click ‘Download’ and ‘Data Transmission’ dialog box appears and displays download processing statues when communication configuration is correctly synchronized. 10th After completing download, ‘Success to download’ message appears.
2 GP Editor Data Download 2.2.2 GP, LP configuration This chaper is described by each of RS422/RS232C serial interface type. For more details, refer to ‘GP Editor user manual’. 2.2.2.1 Mono type 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [SET ENVIRONMENT]-[PLC SETTING]. 3rd CH2 protocol is set as ‘EDITOR’ and CH2 connection port is set as ‘RS232C’ as default. (For donwloading drawn data of GP Editor to GP/LP, use ‘RS232C’ port.
2 GP Editor Data Download 5th If it is not configured as ‘RS232C’ for CH2 connect port even though ‘EDITOR’ for CH2 protocol is configured, touch connect port display item to set ‘RS232C’ as following figure. Connect port display rotates in order as RS422↔RS232C with touching. 6th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor. Touch ‘Menu’, current setting values are saved and it returns to previous menu.
2 GP Editor Data Download 2.2.2.2 Color type 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [Environment]-[Serial Communication]. © Copyright Reserved Autonics Co., Ltd.
2 GP Editor Data Download 3rd CH2 protocol is set as ‘EDITOR’ and CH2 connection port is set as ‘RS232C’ as default. (For donwloading drawn data of GP Editor to GP/LP, use ‘RS232C’ port. In case of using RS232/422 converter, you can download it with RS422 port.) 48 © Copyright Reserved Autonics Co., Ltd.
2 GP Editor Data Download 4th If it is not configured as ‘EDITOR’ for CH2 protocol, touch protocol display item to set ‘EDITOR’ as following figure. Protocol display rotates in order as No Use→EDITOR→ PRINTER→BARCODE→MONITOR with touching. © Copyright Reserved Autonics Co., Ltd.
2 GP Editor Data Download 5th If it is not configured as ‘RS232C’ for CH2 connect port even though ‘EDITOR’ for CH2 protocol is configured, touch connect port display item to set ‘RS232C’ as following figure. Connect port display rotates in order as RS422↔RS232C of two communication connector with touching. 6th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor.
3 PLC Communication 3 PLC Communication 3.1 Communication configuration For communicating GP/LP with PLC, you should designate detail configuration as following before communicating. This chapter is described by LS Master-K200 and Autonics CT6M-2P as example. 3.1.1 GP Editor configuration Through GP Editor which is dedicated drawn software, you can download the data to GP/LP. To download data editing in GP Editor to PLC, you should designate connected PLC group, type, and communication type.
3 PLC Communication 3.1.2 GP, LP configuration 3.1.2.1 Mono type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. After downloading drawn data from GP Editor: After downloading PLC protocol of CH1, CH2 which is designated from GP Editor to GP/LP, it starts communication between the specified PLC and GP/LP through communication configuration. 1st Enter system setting menu.
3 PLC Communication 4th After downloading CH1 protocol is set as downloaded protocol ‘LS MASTER K200’ and CH2 protocol is set as ‘EDITOR’. Touch protocol display item of CH2 to set as downloaded protocol ‘AUTONICS CT6M-2P’. 5th To communicate between GP/LP and LS Master-K200 for CH1, desigante the connect port for the specific PLC and use the dedicated cable. (Refer to ‘4 Communication Cable By Device’) In case of LS Master-K200, it uses CPU module RS232C port. Set connect port item of CH1 as ‘RS232C’.
3 PLC Communication 8th To communicate between GP/LP and Autonics CT6M-2P for CH2, designate the connect port for the specific PLC and use the dedicated cable. (Refer to ‘4 Communication Cable By Device’) In case of Autonics CT6M-2P, it uses RS422 port. Set connect port item of CH2 as ‘RS422’. Connect port display rotates in order as RS422↔RS232C with touching. 9th Synchronize the station of between GP/LP and Autonics CT6M-2P. The station of CH2 is set from link device of GP Editor. (Refer to ‘1.
3 PLC Communication 3.1.2.2 Color type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. After downloading drawn data from GP Editor: After downloading PLC protocol of CH1, CH2 which is designated from GP Editor to GP/LP, it starts communication between the specified PLC and GP/LP through communication configuration. 1st Enter system setting menu. Touch left-upper point as default position of system setting menu.
3 PLC Communication 3rd CH1 protocol is set as following the designated PLC from GP Editor. CH1 is designated as LS MASTER-K200 and CH2 is designated as AUTONICS CT6M-2P from GP Editor. 56 © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 4th After downloading CH1 protocol is set as downloaded protocol ‘LS MASTER K200’ and CH2 protocol is set as ‘EDITOR’. Touch protocol display item of CH2 to set as downloaded protocol ‘AUTONICS CT6M-2P’. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 5th To communicate between GP/LP and LS Master-K200 for CH1, desigante the connect port for the specific PLC and use the dedicated cable. (Refer to ‘4 Communication Cable By Device’) In case of LS Master-K200, it uses CPU module RS232C port. Set connect port item of CH1 as ‘RS232C’. Connect port display rotates in order as RS422↔RS232C with touching. 58 © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 6th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and LS Master-K200. The communicate specification of downloaded PLC to GP/LP is set as default of the connected PLC and communication is available directly. (Only when the communicate specification of connected PLC is set as default) Touch ‘SET’ and designate detailed configuration. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 7th To communicate between GP/LP and Autonics CT6M-2P for CH2, designate the connect port for the specific PLC and use the dedicated cable. (Refer to ‘4 Communication Cable By Device’) In case of Autonics CT6M-2P, it uses RS422 port. Set connect port item of CH2 as ‘RS422’. Connect port display rotates in order as RS422↔RS232C with touching. 8th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and Autonics CT6M-2P.
3 PLC Communication 3.2 1:1 communication It is able to communicate between a GP/LP and a PLC or controller. Mono type, 1:1 communication is available from both CH1, and CH2. Tags (numeral input/display, ASCII input/display) are available to communicate from only CH1, CH2 is available from link device. (Refer to ‘GP Editor user manual’ or ‘1.4 Link device’ of this manual.) Color type, 1:1 communication is available from both CH1, and CH2.
3 PLC Communication 3.2.3 GP, LP configuration 3.2.3.1 Mono type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. After downloading drawn data from GP Editor: After downloading PLC protocol of CH1, CH2 which is designated from GP Editor to GP/LP, it starts communication between the specified PLC and GP/LP through communication configuration. 1st Enter system setting menu.
3 PLC Communication 5th Synchronize the station of between GP/LP and LS Master-K200. Touch CH1 station item and input key pad appears. Enter the same station of LS Master-K200. 6th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and LS Master-K200. The communicate specification of downloaded PLC to GP/LP is set as default of the connected PLC and communication is available directly.
3 PLC Communication 3.2.3.2 Color type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. After downloading drawn data from GP Editor: After downloading PLC protocol of CH1, CH2 which is designated from GP Editor to GP/LP, it starts communication between the specified PLC and GP/LP through communication configuration. 1st Enter system setting menu. Touch left-upper point as default position of system setting menu.
3 PLC Communication 3rd CH1 protocol is set as following the designated PLC from GP Editor. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 4th To communicate between GP/LP and LS Master-K200 for CH1, desigante the connect port for the specific PLC and use the dedicated cable. (Refer to ‘4 Communication Cable By Device’) In case of LS Master-K200, it uses CPU module RS232C port. Set connect port item of CH1 as ‘RS232C’. Connect port display rotates in order as RS422↔RS232C with touching. 66 © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 5th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and LS Master-K200. The communicate specification of downloaded PLC to GP/LP is set as default of the connected PLC and communication is available directly. (Only when the communicate specification of connected PLC is set as default) Touch ‘SET’ and designate detailed configuration.
3 PLC Communication 3.3 1:N communication It is able to communicate between a GP or LP and the number ‘N’ of PLCs or controllers. All of connected PLCs for 1:N communication have to be same type, have RS422(or RS485) port and able to set the station for 1:N communication. In case of mono type, 1:N communication is available by link device of CH2.
3 PLC Communication The below is RS422 communication connection diagram for 1:N communication. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 3.3.2 Communication configuration This chapter is described 1:N communication by CT6M-2P of Autonics’s counter/timer series as example. 3.3.2.1 GP Editor configuration 1st Designate GP/LP and PLC type. Item 70 Note ①GP/LP Type Description Designate GP/LP model type by pulldown menu. ②CH1 Group Designate PLC group of CH1 by pulldown menu. ③CH1 Type Designate PLC type of CH1 for ② by pull-down menu. For mono type, 1:1 communication is not available from CH2.
3 PLC Communication 2nd Select [Common]-[Link Deivce] and ‘Link Device Setting’ dialog box appears. Designate the station of connected PLC to CH2 and connect device. Communication operates as below table.
3 PLC Communication In case of mono type, 1:N communication configuration is available only from link device. For more details, refer to ‘1.4 Link device’. In case of color type, it is available by setting PLC station and device directly from tag (numeral input/display, ASCII input/display) of CH1, CH2 and by by link device. 3rd Draw the data to download for GP/LP from GP Editor. In case of mono type: Supports 1:N communication by CH2.
3 PLC Communication 3.3.2.2 GP, LP configuration (1) Mono type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. After downloading drawn data from GP Editor: After downloading PLC protocol (CT6M-2P) of CH2, it starts communication between the specified PLC and GP/LP through communication configuration. 1st Enter system setting menu. Touch left-upper point as default position of system setting menu.
3 PLC Communication 5th Synchronize the station of between GP/LP and CT6M-2P. The station of CH1 is available to set from GP/LP. CH2 is set from link device of GP Editor. (Refer to ‘1.4 Link device’.) Enter the same station of CT6M-2P. For more details, refer to ‘GP Editor user manual’. 6th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and CT6M-2P.
3 PLC Communication (2) Color type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. (Refer to ‘3.1.2.2 Color type’.) After downloading drawn data from GP Editor: After downloading PLC protocol of CH1, CH2 which is designated from GP Editor to GP/LP, it starts communication between the specified PLC and GP/LP through communication configuration. 1st Enter system setting menu.
3 PLC Communication 3rd CH2 protocol is set as CT6M-2P as PLC type from GP Editor but downloaded CT6M2P protocol is not applied directly. (Communicates with EDITOR from CH2). Touch protocol display item of CH2 to set CT6M-2P. 76 © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 4th To communicate between GP/LP and CT6M-2P, desigante the connect port for the specific PLC and use the dedicated cable.(Refer to ‘4 Communication Cable By Device’.) In case of CT6M-2P, it uses Modbus RS485(RS422) port. Set connect port item of CH2 as ‘RS422’. Connect port display rotates in order as RS422↔RS232C with touching. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 5th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and CT6M-2P. The communicate specification of downloaded PLC to GP/LP is set as default of the connected PLC and communication is available directly. (Only when the communicate specification of connected PLC is set as default) Touch ‘SET’ and detailed configuration screen is switched. Designate detailed configuration.
3 PLC Communication 3.4 Heterogeneous communication 3.4.1 System organization It is able to communicate between GP or LP and PLC or controller by connecting heterogeneous PLC to each port RS232C and RS422 of GP/LP. GP/LP transits communicates between CH1 and CH2 by the designated inner link device. Heterogeneous communication is available by the following system organization such as CH1(1)↔GP(1)↔CH2(1) or CH1(1)↔GP(1)↔CH2(N). CH1 should be one device.
3 PLC Communication 3.4.2 Communication configuration This chapter is described by LS MASTER K200 and MITSUBISHI FX2N as example. 3.4.2.1 GP Editor configuration 1st Designate GP/LP and PLC type. Item ①GP/LP Type Description Designate GP/LP model type by pull-down menu. ②CH1 Group Designate PLC group of CH1 by pull-down menu. ③CH1 Type Designate PLC type of CH1 for ② by pull-down menu. ④CH2 Group Designate PLC group of CH2 by pull-down menu.
3 PLC Communication 3rd Designate each link device of CH1, CH2. For heterogeneous communication, you should designated ① CH1 inner link device and ② CH2 inner link device as same. Click ③Add and desigante CH1, CH2 connect device to communicate. Desiganted link devices are displayed on ④ as list. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication Communication operates as below table. (For more details, refer to ‘1.
3 PLC Communication 3.4.3 GP, LP configuration 3.4.3.1 Mono type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. (Refer to ‘3.1.2.1 Mono type’.) 1st After downloading drawn data from GP Editor, enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [SET ENVIRONMENT]-[PLC SETTING]. 3rd CH1 protocol is set as LS MASTER K200 as PLC type from GP Editor.
3 PLC Communication In case of LS MASTER K200 of CH1, it uses CPU module RS422 port. In case of MITSUBISHI FX2N for CH2, it uses CPU module RS232 and RS232/422 converter should be used. If two of RS232C serial interface type, connect RS232/422 converter at each RS232C A, or RS232C B port. 6th Synchronize the station of between GP/LP and connected devices. The station of CH1 is available to set from GP/LP. CH2 is set from link device of GP Editor. (Refer to ‘1.4 Link device’.
3 PLC Communication 3.4.3.2 Color type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. 1st After downloading drawn data from GP Editor, enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [Environment]-[Serial Communication]. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 3rd CH1 protocol is set as LS MASTER K200 as PLC type from GP Editor. CH1 is designated as LS MASTER-K200 and CH2 is designated as MITSUBISHI FX2N from GP Editor. CH2 protocol is set as MITSUBISHI FX2N as PLC type from GP Editor but downloaded MITSUBISHI FX2N protocol is not applied directly. (Communicates with EDITOR from CH2). Touch protocol display item of CH2 to set MITSUBISHI FX2N. 86 © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 4th To communicate between GP/LP and LS MASTER K200 for CH1, MITSUBISHI FX2N for CH2, desigante the connect port for the specific PLC and use the dedicated cable. (Refer to ‘4 Communication Cable By Device’) In case of LS MASTER K200 of CH1, it uses CPU module RS232 port. In case of MITSUBISHI FX2N for CH2, it uses CPU module RS232 and RS232/422 converter should be used. If two of RS232C serial interface type, connect each RS232C A, or RS232C B port. © Copyright Reserved Autonics Co.
3 PLC Communication 5th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and connected devices by each CH1, CH2. The communicate specification of downloaded PLC to GP/LP is set as default of the connected PLC and communication is available directly. (Only when the communicate specification of connected PLC is set as default) Touch ‘SET’ of CH1 or CH2 and detailed configuration screen is switched. Designate detailed configuration by each channel.
3 PLC Communication 6th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor with connected devices CH1(LS MASTER K200), CH2(MITSUBISHI FX2N). Touch ‘BEFORE’, current setting values are saved and it returns to previous menu. Touch ‘CLOSE’, current setting values are saved and it returns to user screen after exiting system setting menu. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 3.5 Other communication 3.5.1 System organization GP, LP is able to connect with barcode reader and printer to communicate,system organization is as following. 3.5.2 Barcode reader communication configuration Basic communication for PLC↔GP/LP↔Barcode reader is by RS232C communication for barcode reader to GP/LP, by RS422 for PLC to GP/LP. GP/LP is designed for any RS232C, RS422 communication. With RS232/422 converter, the opposite case is also available.
3 PLC Communication 3.5.2.2 GP, LP configuration (1) Mono type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. 1st After downloading drawn data from GP Editor, enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [SET ENVIRONMENT]-[PLC SETTING]. 3rd CH2 protocol is set as ‘EDITOR’ as basic configuration. 4th Touch protocol display item to set ‘BARCODE’ as following figure.
3 PLC Communication 6th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and barcode reader. Touch ‘CH2’ and detailed configuration screen is switched. Designate detailed configuration. 7th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor with barcode reader. Touch ‘Menu’, current setting values are saved and it returns to previous menu.
3 PLC Communication 2nd Select [Environment]-[Serial Communication]. 3rd CH2 protocol is set as ‘EDITOR’ as basic configuration. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 4th Touch protocol display item to set ‘BARCODE’ as following figure. Protocol display rotates in order as EDITOR→PRINTER→BARCODE→MONITOR with touching. 94 © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 5th Designate connect port for communicating GP/LP and barcode reader. Connect port display rotates in order as RS422↔RS232C with touching. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 6th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and barcode reader. Touch ‘SET’ and detailed configuration screen is switched. Designate detailed configuration. 7th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor with barcode reader. Touch ‘BEFORE’, current setting values are saved and it returns to previous menu.
3 PLC Communication 3.5.3 PRINTER communication configuration Basic communication for PLC ↔ GP/LP ↔ PRINTER is same as barcode reader communication’s. PLC and PRINTER are available to both RS232C and RS422 communication and printer through GP/LP is able to print alarm history. The other words, if there are alarm history in downloaded data from GP Editor, and saved alarm history by communicating GP/LP and PLC, you can print out alarm history through GP/LP and printer. 3.5.3.
3 PLC Communication 4th Touch protocol display item to set ‘PRINTER’ as following figure. Protocol display rotates in order as EDITOR→PRINTER→BARCODE→MONITOR with touching. 5th Designate connect port for communicating GP/LP and printer. Connect port display rotates in order as RS422↔RS232C with touching. 6th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and printer. Touch ‘CH2’ and detailed configuration screen is switched.
3 PLC Communication (2) Color type Before downloading drawn data from GP Editor: Synchronize communication configurations of between GP/LP and GP Editor. 1st After downloading drawn data from GP Editor, enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [Environment]-[Serial Communication]. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 3rd CH2 protocol is set as ‘EDITOR’ as basic configuration. 4th Touch protocol display item to set ‘PRINTER’ as following figure. Protocol display rotates in order as EDITOR→PRINTER→BARCODE→MONITOR with touching. 100 © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 5th Designate connect port for communicating GP/LP and printer. Connect port display rotates in order as RS422↔RS232C with touching. © Copyright Reserved Autonics Co., Ltd.
3 PLC Communication 6th Synchronize communicate specifications (baudrate, data bit, stop bit, parity, flow control) of between GP/LP and printer. Touch ‘SET’ and detailed configuration screen is switched. Designate detailed configuration. 7th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor. Touch ‘BEFORE’, current setting values are saved and it returns to previous menu.
3 PLC Communication 3.6 System signal 3.6.1 System signal 1 (GP/LP ← PLC) System signal 1 [ UW15 ] F E D C B A 9 8 7 6 5 4 3 2 1 0 1 Word It is allocated in GP/LP inner word device UW15(UB150 to UB15F). Bit 0 (UB150): It clears all alarm histories (history and the number of occurring time) when this bit is rising trigger of OFF→ON.
3 PLC Communication 3.6.2 System signal 2 (GP/LP → PLC) System signal 2 [UW4] F E D C B A 9 8 7 6 5 4 3 2 1 0 1 Word It is allocated in GP, LP inner word device UW4(UB40 to UB4F). 104 Bit 0 (UB40): This bit is ON while any of alarm monitor bit is ON. Bit 1 (UB41) Bit 2 (UB42) Bit 3 (UB43) Bit 4 (UB44): This bit turns ON when numeral input is completed. This bit is OFF when (bit7 of system signal 1) is ON.
3 PLC Communication 3.6.3 System signal 3 (GP/LP ← PLC) System signal 3 [UW17] F E D C B A 9 8 7 6 5 4 3 2 1 0 1 Word It is allotted in GP, LP inner word device UW17(UB170 to UB17F). Bit 0 (UB170): Buzzer turns ON when this bit is changed from OFF to ON. Buzzer turns OFF when this bit is changed from ON to OFF. Buzzer turns OFF when user touches the screen, this bit maintains ON status.
3 PLC Communication 3.6.4 System signal 4 (GP/LP → PLC) System signal 4 [UW5] F E D C B A 9 8 7 6 5 4 3 2 1 0 1 Word It is allotted in GP, LP inner word device UW5 (UB50 to UB5F). 106 Bit 0 (UB50): It turns ON during printing an alarm. Bit 1 (UB51) Bit 2 (UB52) Bit 3 (UB53) Bit 4 (UB54) Bit 5 (UB55): It turns ON when 0.5 sec of clock occurs. (Only for GP) Bit 6 (UB56): It turns ON when 1 sec of clock occurs.
4 Communication Cable By Device 4 Communication Cable By Device 4.1 Ordering information 4.2 Cable wiring and dimensions (1) C3M5P00-D9F0-M6MO (2) C3M5P01-D9F0-D9M0 (3) C3M5P02-D9F0-D9M0 © Copyright Reserved Autonics Co., Ltd.
4 Communication Cable By Device (4) C3M5P03-D9M0-W4*0 (5) C3M5P04-D9M0-W6*0 (6) C3M5P05-D9F0-D9M0 (7) C3M5P06-D9F0-D15M0 (8) C3M5P07-D9F0-D9M0 (9) C3M5P08-D9M0-M8M0 108 © Copyright Reserved Autonics Co., Ltd.
4 Communication Cable By Device (10) C3M5P09-D9F0-D9F0 (11) C3M5P10-D9F0-M5M0 (12) C3M5P11-D9F0-W4*0 (13) C3M5P12-D9F0-D9M1 (14) C3M5P13-D9F0-T4Y0 (15) C3M5P03-D9M0-T4Y0 © Copyright Reserved Autonics Co., Ltd.
4 Communication Cable By Device (16) C3M5P04-D9M0-T6Y0 (17) C3M5P03-D9F0-D9F0 (18) C3M5P03-D9M0-D9M0 (19) C3M5P08-D9M0-M8M1 110 © Copyright Reserved Autonics Co., Ltd.
4 Communication Cable By Device 4.
4 Communication Cable By Device Series OEMAX OEMAX FARA Connectable device Connection module Communication connection type Communication cable model name Communica tion cable wiring number N70 CPU RS232C C3M5P06-D9F0-D15M0 7 N70Plus CPU RS232C C3M5P07-D9F0-D9M0 8 NX7 CPU RS232C C3M5P07-D9F0-D9M0 8 NX70 CPU RS232C C3M5P07-D9F0-D9M0 8 CPU RS422 C3M5P08-D9M0-M8M0 9 RS232C (FX1S-232BD) RS232C C3M5P09-D9F0-D9F0 10 FX1S MITSUBISHI FX CPU RS422 C3M5P08-D9M0-M8M0 9 FX1N R
4 Communication Cable By Device Series Connectable device Connection module Extension module QJ71C24NR2 QJ71C24NR4 Extension module QJ71C24N Q02H Extension module QJ71C24NR2 Extension module QJ71C24NR4 Extension module QJ71C24N Q06H Extension module QJ71C24NR2 Extension module QJ71C24NR4 Extension module QJ71C24N Q12H Extension module QJ71C24NR2 Extension module QJ71C24NR4 Extension module QJ71C24N Q25H FP0-C16 NAIS FP FP0-C32 FP0-T32C FPG-C24R2 Extension module QJ71C24NR2 Extension module QJ
4 Communication Cable By Device Series Connectable device FPG-C32T FPG-C32T2 FP0R-C10 FP0R-C14 FP0R-C16 FP0R-C32 FP0R-T32 FP0R-F32 SIEMENS SIMATIC S7-200 SIEMENS SIMATIC S7-300 Allen-Bradley 114 Connection module CPU(COM port) CPU(Tool port) CPU(COM port) CPU(Tool port) CPU(COM port) CPU(Tool port) CPU (COM port) CPU(Tool port) CPU (COM port) CPU(Tool port) CPU(COM port) CPU(Tool port) CPU(COM port) CPU(Tool port) CPU(COM port) CPU(Tool port) CPU(COM port) Communication connection type Comm
4 Communication Cable By Device Series Connectable device MicroLogix 1200 MicroLogix 1500 OMRON SYSMAC C CPM1A E5AN OMRON temperature controller Connection module Communication connection type CPU RS232C CPU RS232C CPU CPU direct Communication cable model name Dedicated cable for AllenBradley Dedicated cable for AllenBradley Communica tion cable wiring number - For communicating GP, CQM1-CIF02 of OMRON - For extension cable, C3M5P12-D9F0-D9M1 13 RS232C C3M5P13-D9F0-T4Y0 14 RS485 C3M
4 Communication Cable By Device 116 © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 5 Universal (General-purpose communication) Universal indicates general purpose of communication, Modbus Slave communication is supported in GP/LP. 5.1 System organization Microcomputer using as host unit is able to execute slave communicate with GP/LP through RS232C or RS-422(RS-485) communication port. Host unit read and write inner register(UB, UW) of GP/LP as communication commander.
5 Universal (General-purpose communication) 5.2 Universal 1:1 communication Universal 1:1 indicates communication between one host unit and one GP/LP to monitor GP/LP status.(It is able to extend.) 5.2.1 GP Editor configuration Universal communication is available only by CH1. 1st Designate GP/LP and PLC type. Item ①GP/LP Type Description Designate GP/LP model type by pull-down menu. ②CH1 Group Designate PLC group of CH1 by pull-down menu.
5 Universal (General-purpose communication) 5.2.2 GP, LP configuration 5.2.2.1 Mono type You should desigante CH1 protocol as ‘UNIVERSAL’ and set communication configuration for CH1 in GP/LP. 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [SET ENVIRONMENT]-[PLC SETTING]. 3rd CH1 protocol is set as ‘UNIVERSAL’ and CH1 connection port is set as ‘RS422’ as default.
5 Universal (General-purpose communication) 6th Synchronize the station of between GP/LP and host unit. Touch CH1 station item and input key pad appears. Enter the same station and setting range is 1 to 31. 7th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor with host unit. Touch ‘Menu’, current setting values are saved and it returns to previous menu.
5 Universal (General-purpose communication) 2nd Select [Environment]-[Serial Communication]. 3rd CH1 protocol is set as ‘UNIVERSAL’ and CH1 connection port is set as ‘RS422’ as default. © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 4th If it is not configured as ‘UNIVERSAL’ for CH1 protocol, touch protocol display item to set ‘UNIVERSAL’ as following figure. Protocol display rotates in order as UNIVERSAL→MK-200S(CPU)→No Use→ PRINTER→BARCODE with touching. 122 © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 5th Synchronize CH1 connect port display item with touching. © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 6th Synchronize the station of between GP/LP and host unit. Touch the station item and input key pad appears. Enter the same station and setting range is 1 to 31. 7th After completing communication configuration, you should exit system setting menu and switch user screen to communicate GP Editor with host unit. Touch ‘BEFORE’, current setting values are saved and it returns to previous menu.
5 Universal (General-purpose communication) 5.3 Universal 1:1:1 communication Universal 1:1:1 indicates communication between one host unit, one GP/LP and one PLC which is connected to GP/LP. 5.3.1 GP Editor configuration When CH1 group is set as ‘AUTONICS UNIVERSAL’ , CH1 type is set automatically as ‘UNIVERSAL’. At CH2 configuration, designate PLC group and type to be connected to GP/LP. 1st Designate GP/LP and PLC type.
5 Universal (General-purpose communication) Do not designate GP connect device and link device setting of CH1. In this communication, GP/LP is as master and host unit is as slave. Therefore it is not able to communicate between GP/LP and host unit. 5.3.2 GP, LP configuration 5.3.2.1 Mono type 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [SET ENVIRONMENT]-[PLC SETTING].
5 Universal (General-purpose communication) 6th Synchronize CH1 and CH2 connect port display item with touching. 7th Synchronize the station of between GP/LP and host unit. Touch the station item and input key pad appears. Enter the same station and setting range is 1 to 31. 8th After completing communication configuration, you should exit system setting menu and switch user screen to 1:1:1 communication. Touch ‘Menu’, current setting values are saved and it returns to previous menu.
5 Universal (General-purpose communication) 5.3.2.2 Color type 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [Environment]-[Serial Communication]. 128 © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 3rd CH1 protocol is set as ‘UNIVERSAL’ and CH1 connection port is set as ‘RS422’ as default. 4th If it is not configured as ‘UNIVERSAL’ for CH1 protocol, touch protocol display item to set ‘UNIVERSAL’ as following figure. Protocol display rotates in order as UNIVERSAL→MK-200S(CPU)→No Use→ PRINTER→BARCODE with touching. © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 5th Touch protocol display item of CH2 to set ‘MK-200S’ as following figure. 130 © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 6th Synchronize CH1 and CH2 connect port display item with touching. © Copyright Reserved Autonics Co., Ltd.
5 Universal (General-purpose communication) 7th Synchronize the station of between GP/LP and host unit. Touch the station item and input key pad appears. Enter the same station and setting range is 1 to 31. 8th After completing communication configuration, you should exit system setting menu and switch user screen to 1:1:1 communication. Touch ‘BEFORE’, current setting values are saved and it returns to previous menu. Touch ‘CLOSE’, current setting values are saved and it returns to user screen.
5 Universal (General-purpose communication) 5.4 Universal protocol Modbus RTU is a standard. It communicates with host unit as master, GP/LP as slave. In host unit, it transmits Query to GP/LP, GP/LP executes designated operation according to received command and send response. When it receives Query of master and slave does not respond ecause of detection of error including parity, CRC or communication error, master re-transmits Query as timeout.
5 Universal (General-purpose communication) 5.4.3 Communication frame organization 5.4.3.1 Query master part Station Function code Data area ① ② ③ Item CRC L H ④ Description It is slave station (HEX) receiving a message from master. Setting range is 0 to 255. If it is 0, it is broadcast query which sends message to every slave. ①Station ②Function code (HEX) Slave executes designated function according to function code.
5 Universal (General-purpose communication) (4) Preset Multiple Registers(Func16-10H) Slave Address (station) Function (command) 1Byte 1Byte Starting Address (starting address) No.
5 Universal (General-purpose communication) 5.4.3.2 Response slave part Station Function code ① Item ② CRC Data area L ③ Description H ④ ①Station It is slave station (HEX) for confirmation about Query. ②Function code (HEX) Transmits same function code sent by Master for confirmation about Query. ③Data area (HEX) Transmits data related with function code. The length is variable. ④CRC(HEX) It is error check area. It calculates using CRC-16 code. It consists of 2btye.
5 Universal (General-purpose communication) (4) Preset Multiple Registers(Func16-10H) 5.4.3.3 Slave Address (station) Function (command) 1Byte 1Byte Starting Address (starting address) No. of Register (the number of register) Error Check (CRC16) Hi(upper) Lo(lower) Hi(upper) Lo(lower) Lo(lower) Hi(upper) 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte Error Station ① Function code Error code ② ③ CRC L H ④ Item Description ①Station It is slave station (HEX) for confirmation about Query.
5 Universal (General-purpose communication) 5.5 Universal function example 5.5.1 01(Read Coils) It reads contents of successive coil. There is no Broadcast (Station designation of Slave as 0). Available address is 000000 to 65535, it accords slave UB00000 to UB4095F. When reading 5 register data from UB0180 to UB0184 of GP/LP with station no.
5 Universal (General-purpose communication) When calcuating 3000 address as UB Device display Address/16 Quotient Remainder(displays hexadecimal) 3000 187 8 Therefore, address valud 3000 corresponds to UB 1878.
5 Universal (General-purpose communication) 5.5.2 15(Force Multiple Coils) It writes contents of successive coil. When designating (Broadcast) slave station as 0, it writes in same address of slave. Available address is 000240 to 65535, it accords slave UB00150 to UB4094F of GP/LP. In case of writing next data in UB1000 to UB1004 of GP with station no.
5 Universal (General-purpose communication) Response Station Function code Start address 0x05 0x0F 0x06 ① ② ③ 0x40 ④ The number of register 0x00 ⑤ 0x05 CRC 0x95 ⑥ ⑦ 0x10 ⑧ Item Description ①Station Slave station is 05, 05 = (Hex)0x05 ②Function code 15. 15 = (Hex)0x0F ③Start address upper byte Start address is UB1000.
5 Universal (General-purpose communication) 5.5.3 03(Read holding register) It reads contents of successive holding register. There is no Broadcast(Station designation of Slave as 0). Available address is 00000 to 06047, it accords slave UW0000 to UW6047 of GP/LP. In case of reading 5 register data from UW0000 to UW0004 of GP/LP with station no.
5 Universal (General-purpose communication) Response Station Function code 0x1F 0x03 The number of data byte 0x0A ① ② ③ Data 4 0x00 0x00 Data 5 0x00 0x32 ⑩ ⑫ ⑪ ⑬ CRC 0x8F Data 1 0x0A 0x00 0x14 0x00 0x1E ④ ⑤ ⑥ ⑦ ⑧ ⑨ 0xD6 ⑭ ⑮ Description ①Station Slave station ②Function code 03 ④, ⑥Data1 ⑥, ⑦Data2 ⑧, ⑨Data3 ⑩, ⑪Data4 ⑫, ⑬Data5 ⑭, ⑮CRC © Copyright Reserved Autonics Co., Ltd. Data 3 0x00 Item ③the number of data byte Data 2 The total number of byte of data area.
5 Universal (General-purpose communication) 5.5.4 16(Preset multiple register) It writes contents of successive holding register. When designating(Broadcast) slave station as 0, it writes in same address of slave. Available address is 00015 to 06047, it accords slave UW0015 to UW6047 of GP/LP. In case of writing next data in UW100 to UW104 of GP/LP with station no.05.
5 Universal (General-purpose communication) Item ⑭Alternation data 4 upper byte Description Upper byte value of data to write in UW103 ⑮Alternation data 4 lower byte Lower byte value of data to write in UW103 ⑯Alternation data 5 upper byte Upper byte value of data to write in UW104 ⑰Alternation data 5 lower byte Lower byte value of data to write in UW104 ⑱CRC lower byte ⑲CRC upper byte Response Statio n 0x05 Function code 0x10 ① ② Start address 0x00 ③ 0x64 ④ Item The number of register 0
5 Universal (General-purpose communication) 5.5.5 Exception response It transmits function code response after set the most upper bit of function code master transmitted as 1. In case of reading 5 data of input register UW0000 to UW0004 with station no.5. Query 0x05 Function code 0x04 0x00 ① ② ③ Station Start address 0x00 The number of read register 0x00 0x05 ⑤ ④ ⑥ Item Description ①Station Slave station is 05, 05 = (Hex)0x05 ②Function code 04. It is not available code.
6 Connectable PLC 6 Connectable PLC Series Connect device Connect module Connect type Communication cable model name No .
6 Connectable PLC Series Connect device Connect module Connect type Communication cable model name No .
6 Connectable PLC 6.1 Autonics product GP/LP is able to communicate with Autonics multi panel meter(MT series), pulse meter(MP series), temperature/humidity sensor(THD-RT series) and temperature controller(TZ), counter/timer(CT series), display unit (DS/DA series), and digital remote I/O (ARM series). 6.1.1 System organization Autonics MT, MP, THD-RT, TZ, TM, TK, CT, DS/DA, ARM sereis execute RS485 commnication and RS422 communication is available when connecting cable as below.
6 Connectable PLC PLC type Communication method Default baudrate(bps) RS485/422 9600 MT MT(MODBUS) MP THD-RT(MODBUS) Autonics TZ TM(MODBUS) TK(MODBUS) CT(MODBUS) DS/DA(MODBUS) Remote I/O ARM(MODBUS) It should be set same between baudrate, station of Autonics controllers and the baudrate, station of GP/LP. Refer to each product’s user manual for communication configuration and station of each product. Be sure that Autonics controller has devided read/write device for using device.
6 Connectable PLC 6.1.3 Available device 6.1.3.1 MT series Available device and displayed parameter of Autonics MT series are as following. Available device is only for MT series.
6 Connectable PLC 2) Device Description address Enable Read/Write MT30123 Holding REG quantity Read MT30124 Input REG start address Read MT30125 Input REG quantity Read Modbus TYPE A (MT4N_Mod_A) 1 Range Start 100001 End 100001 GP/LP inner bit memory UB UB0 UB6047F Word device area 3 300001 300004 Word device area 3 300101 300109 Word device area 3 300118 300125 UW UW0 UW6047 Type Device Mark Bit Bit device area Bit Word GP/LP inner word memory 152 Device 300001
6 Connectable PLC (3) Modbus communication type in MT series (MT4W, MT4Y) 1) Modbus (MT4W_Mod, MT4Y_Mod) MT Range Start MT10001 End MT10001 GP/LP inner bit memory UB UB0 UB6047F Word device area MT MT30001 MT30004 UW UW0 UW6047 Type Device Mark Bit Bit device area Bit Word GP/LP inner word memory 2) Device MT30001 Description Present value Enable read/write Read MT30002 Dot setting value Read MT30003 Max. signal input Read MT30004 Min.
6 Connectable PLC 6.1.3.2 MP Available device and displayed parameter of Autonics MP series are as following. Available device is only for MP series.
6 Connectable PLC 6.1.3.3 THD-RT(Modbus) Available device and displayed parameter of Autonics THD-RT series are as following. Available device is only for TH series.
6 Connectable PLC (2) Modbus TYPE A(THD-RT_Mod_A ) UB Range Start UB0 End UB6047F Word device area 3 300001 300002 Word device area 3 300101 300125 UW UW0 UW6047 Type Device Mark Bit GP/LP inner bit memory Word GP/LP inner word memory 156 Device 300001 Description Temperature value Enable read/write Read 300002 Humidity value Read … Blank - 300101 Product number H Read 300102 Product number L Read 300103 Hardware version Read 300104 Software version Read 300105
6 Connectable PLC 6.1.3.4 TZ Available device and displayed parameter of Autonics TZ series are as following. Available device is only for TZ series. End UB6047F Word device area TZ TZ0 TZ1 GP/LP inner word memory UW UW0 UW6047 Device Mark Bit GP/LP inner bit memory Word 6.1.3.5 UB Range Start UB0 Type Device TZ0 Description Present value Enable read/write Read TZ1 Setting value Read/Write TM For available device for Autonics TM, refer to ‘TM user manual for communication’.
6 Connectable PLC 6.1.3.6 TK For available device for Autonics TK, refer to ‘TK user manual for communication’.
6 Connectable PLC 6.1.3.8 DS/DA For available device for Autonics display unit DS/DA series, refer to ‘CT user manual for communication’. Type Device Mark Bit GP/LP inner bit memory UB Range Start UB0 Word device area 3 Refer to DS/DA device table Word device area 4 Refer to DS/DA device table GP/LP inner word memory UW UW0 Word 6.1.3.9 End UB6047F UW6047 Remote I/O ARM For available device for Autonics remote I/O ARM series, refer to ‘CT user manual for communication’.
6 Connectable PLC 6.1.4 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.1.3 Available device’. 6.1.4.1 MT series (1) Modbus Type Mark Bit UB Word 6.1.4.
6 Connectable PLC 6.1.4.4 TZ series Type Bit Word 6.1.4.5 Mark UB GP/LP inner bit memory Device TZ Data register UW GP/LP inner word memory TM series (1) Modbus Type Mark TM Bit UB Word Bit Word Device Bit device area Note GP/LP inner bit memory TM Word device area UW GP/LP inner word memory (2) Modbus TYPE A Type Mark 0 6.1.4.
6 Connectable PLC 6.1.4.7 CT series (1) Modbus Type Mark CT Bit UB Word Word 6.1.4.8 6.1.4.
6 Connectable PLC 6.2 Autonics LP series PLC connection GP/LP is able to connect with Autonics LP series. 6.2.1 System organization Autonics LP sereis executes RS-232C commnication. It executes also RS-422 communication with RS-232/422 converter.
6 Connectable PLC 6.2.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error.
6 Connectable PLC 6.2.2.
6 Connectable PLC 6.2.2.
6 Connectable PLC 6.2.3 Monitorable device in GP/LP GP/LP is able to monitor LP and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.2.2 Available device’.
6 Connectable PLC 6.3 LS Master-K series PLC connection GP/LP is able to communicate with LS Master-K series. 6.3.1 System organization LS Master-K sereis executes RS232C commnication. If PLC has imbeded RS422 loader port or you use RS232/422 converter, RS422 communication is also available. PLC type LS Master K Communication method Communication type RS232C CPU direct(Loader) MK-10S1 MK-80S/120S/200S/ 300S/1000S Baud rate (bps) 9600 38400 RS232C cable is different by connected PLC type.
6 Connectable PLC 6.3.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. Bit device; P, M, K, F, L are not used as general word at PLC. However, it is able to switch into word UW device binding 16 units in GP/LP. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units.
6 Connectable PLC 6.3.2.
6 Connectable PLC 6.3.2.
6 Connectable PLC 6.3.2.
6 Connectable PLC 6.3.2.
6 Connectable PLC 6.3.2.
6 Connectable PLC 6.3.2.
6 Connectable PLC 6.3.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.3.2 Available device’.
6 Connectable PLC 6.4 LS Glofa PLC connection GP/LP is able to communicate with LS Glofa series. 6.4.1 System organization LS Glofa sereis executes RS232C commnication. If PLC has imbeded RS422 loader port or you use RS232/422 converter, RS422 communication is also available. PLC type Communication method Communication type Baudrate (bps) RS232C CPU direct(Loader) 38400 GM4 LS Glofa GM6 GM7U The following is RS232C cable diagram and pin arrangement. © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.4.2 Available device Display method for variable in GP/LP is used by direct display method for variable. Bit device uses IX, QX, MX only, word device uses IW, QW, MW only. Device range is different depending on PLC model. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error.
6 Connectable PLC 6.4.2.1 Structure differences of use device for GP/LP and GMWIN (1) Input/Output relay of bit device structure I/O bit device structure for GMWIN %[Device name] [Base number] . [Slot number]. [(The number of I/O card point X 16)+Bit address] I/O bit device structure for GP [Device name] [Base number] [Slot number] [The number of I/O card point] [Bit address (Hexadecimal)] Output device; Base number=2, Slot number=1, The number of I/O card point=2, Bit address=10 %QX 2.1.
6 Connectable PLC 6.4.2.3 GM6 Type Bit Word 6.4.2.
6 Connectable PLC 6.5 LS XGB Series PLC communication connection GP/LP is able to communicate with LS XGB series PLC and Cnet. 6.5.1 System organization It executes Cnet communication with GP/LP connecting directly with PLC CPU or using Cnet Unit. It is able to execute Cnet communication differenting pin number of Loarder port in CPU and connecting Cnet Unit. 6.5.1.
6 Connectable PLC 6.5.1.2 When using Cnet Unit, PLC type XBM LS XGB CNET XBC Unit model Communication name method XBL-C21A RS232C XBL-C41A RS422 XBL-C21A RS232C XBL-C41A RS422 Baudrate(bps) 19200 (1) Cnet Unit RS-232C(Applied cable (6)C3M5P05-D9F0-D9M0) (2) Cnet Unit RS-422(Applied cable (16)C3M5P04-D9M0-T6Y0) 182 © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.5.2 Communication configuration Communication configuration when using Cnet, In XG-PD program, configure Cnet to LS XGB series. (For more information, please refer to the manual from LSIS.) 1st Select [File]-[New File] and ‘New Project’ dialog box opens. Select the CPU kind. 2nd At the Project window, right-click ‘00: Embedded Cnet’ the last of Test items and click ‘Module Settings’ from pop-up menu. ‘Standard Settings – Cnet’ dialog box appears. © Copyright Reserved Autonics Co.
6 Connectable PLC 3rd Configure the settings as same as the communication setting of GP/LP. 4th Connect the unit and Cnet Unit with communication cable. 184 © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.5.
6 Connectable PLC (2) XBC Series Type Bit Word 186 Device Mark Input relay Range Start End P P0 P1023F Output relay P P0 P1023F Inner auxiliary relay M M0 M1023F Memory protection relay K K0 K4095F Special relay F F0 F1023F Link relay L L0 L2047F Timer contact T T0 T1023 Counter contact C C0 C1023 GP inner bit memory UB UB0 UB6047F Input relay P P0 P1023 Output relay P P0 P1023 Inner auxiliary relay M M0 M1023 Memory protection relay K K0 K4095 Sp
6 Connectable PLC 6.5.4 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is available device list of this menu, and available range is same as ‘6.5.3 Available device’.
6 Connectable PLC 6.6 LS XGT Series PLC communication connection GP/LP is able to communicate with LS XGT series PLC. 6.6.1 System organization It executes Cnet communication with GP/LP using Cnet Unit. 6.6.1.
6 Connectable PLC 6.6.2 Communication configuration In XG-PD program, configure Cnet to LS XGT seires. (For more information, please refer to the manual from LSIS.) 1st Select [File]-[New File] and ‘New Project’ dialog box opens. Select the CPU kind. 2nd At the Project window, select the configured PLC and right-click ‘Add Module’ from pop-up menu. 3rd Communication Module Setting dialog box apperas. Select Type as ‘Cnet’. © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 4th At the Project window, double-click the added communication module and ‘Standard Settings – Cnet’ dialog box appears. 5th Configure the settings as same as the communication setting of GP/LP. 6th Connect the unit and Cnet Unit with communication cable. 190 © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.6.
6 Connectable PLC 6.6.4 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is available device list of this menu, and available range is same as ‘6.6.3 Available device’.
6 Connectable PLC 6.7 LS Cnet communication connection GP/LP is able to communicate with LS Cnet. 6.7.1 System organization It executes Cnet communication with GP/LP connecting directly with PLC CPU or using Cnet Unit. It is able to execute Cnet communication differing pin number of Loader port in CPU and connecting Cnet Unit. 6.7.1.
6 Connectable PLC (1) RS-232C (Applied cable (3)C3M5P02-D9F0-D9M0) (2) RS-422(Applied cable (5)C3M5P04-D9M0-W6*0) (3) RS-485 (Applied cable (4)C3M5P03-D9M0-W4*0) 194 © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.7.1.2 When using Cnet Unit, Unit model name G7L-CUEB Communication method RS232C G7L-CUEC RS422 G7L-CUEB RS232C G7L-CUEC RS422 G6L-CUEB RS232C G6L-CUEC RS422 MK-300S G4L-CUEA RS232C, RS422 MK-1000S G3L-CUEA RS232C, RS422 PLC type MK-80S MK-120S LS Master-K MK-200S Baudrate (bps) 19200 In case of K7M-DR10S CPU of MK-80S, Cnet Unit cannot be connetable.
6 Connectable PLC 6.7.2.2 Communication configuration when using Cnet Unit Configuration LS Master-K seires Cnet Communication configuration for using Cnet Unit is set from Cnet Frame Editor and communication configuration method is as following. (You can download the program from LSIS website.) 3rd Connect PC and lodder port in PLC CPU with RS232C cable. 4th Execute Cnet Frame Editor. 5th Select [Online]-[Connect] of menu and set the status to communication with PLC.
6 Connectable PLC 6.8 OEMAX PLC(Samsung PLC) connection GP/LP is able to communicate with Samsung FARA N series and N plus series. 6.8.1 System organization Samsung FARA sereis executes RS232C commnication. If PLC has imbeded RS422 loader port or you use RS232/422 converter, RS422 communication is also available.
6 Connectable PLC (2) 6.8.2 Connect PLC is N70plus, NX7, NX70 (Applied cable (8)C3M5P07D9F0-D9M0) Available device Be sure that device address of N70 and N70plus are different structure. 6.8.2.1 FARA N70 Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC.
6 Connectable PLC Type Bit Word X Range Start X0 End X127F Output relay Y Y0 Y127F Inner auxiliary relay R R0 R97F Special relay R R9000 R910F Link relay L L0 L127F Timer contact[10ms] T T0 T199 Timer contact[100ms] T T0 T199 Timer contact[1000ms] T T0 T199 Counter contact[16bit] C C200 C255 GP/LP inner bit memory UB UB0 UB6047F Input relay WX WX0 WX127 Output relay WY WY0 WY127 Inner auxiliary relay WR WR0 WR97 Link relay WL WL0 WL127 Timer present
6 Connectable PLC 6.8.2.2 FARA N70 Plus Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. Bit device; R, M, K, F, L are not used as general word at PLC. However, it is able to switch into word UW device binding 16 units in GP/LP. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units.
6 Connectable PLC Word R1 = Bit R100 to R115 , Word UW10 = UB100 to UB10F There is difference for mark of bit R, M, K, F, L between general mark and GP/LP mark. General mark is displayed as R##.##, GP/LP mark is displayed without middle of distinguisher. For example, R10.10 is displayed as ‘R1010’ in GP/LP. Be sure that GP/LP does not use distinguisher, it uses virtual distinguisher cutting two digits from the backward of input bit R, M, K, F, L address. (Ex) Bit R1 = R0.01 , Bit M10 = M0.
6 Connectable PLC 6.8.2.3 FARA NX7 Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. Bit device; R, M, K, F, L are not used as general word at PLC. However, it is able to switch into word UW device binding 16 units in GP/LP. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units.
6 Connectable PLC Word R1 = Bit R100 to R115 , Word UW10 = UB100 to UB10F There is difference for mark of bitR, M, K, F, L between general mark and GP/LP mark. General mark is displayed as R##.##, GP/LP mark is displayed without middle of distinguisher. For example, R10.10 is displayed as ‘R1010’ in GP/LP. Be sure that GP/LP does not use distinguisher, it uses virtual distinguisher cutting two digits from the backward of input bit R, M, K, F, L address. (Ex) Bit R1 = R0.01 , Bit M10 = M0.
6 Connectable PLC 6.8.2.4 FARA NX70 (CPU70) Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point Bit device; R, M, K, F, L are not used as general word at PLC. However, it is able to switch into word UW device binding 16 units in GP/LP. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units.
6 Connectable PLC Word R1 = Bit R100 to R115 , Word UW10 = UB100 to UB10F There is difference for mark of bit R, M, K, F, L between general mark and GP/LP mark. General mark is displayed as R##.##, GP/LP mark is displayed without middle of distinguisher. For example, R10.10 is displayed as ‘R1010’ in GP/LP. Be sure that GP/LP does not use distinguisher, it uses virtual distinguisher cutting two digits from the backward of input bit R, M, K, F, L address. Bit R1 = R0.01 , Bit M10 = M0.10 , Bit K101 = K1.
6 Connectable PLC 6.8.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.6.2 Available device’. 6.8.3.
6 Connectable PLC 6.8.3.
6 Connectable PLC 6.9 MITSUBISHI PLC GP/LP is able to communicate with MITSUBISHI FX series. 6.9.1 System organization FX sereis executes RS422 commnication and it executes also RS232C communication with RS232/422 converter or RS232C communication board (FX1N-232-BD, FX2N-232-BD).
6 Connectable PLC (1) RS-422: Applied cable (9)C3M5P08-D9M0-M8M0. (2) RS-232C communication board(FX1N/FX2N-232-BD): Applied cable (10)C3M5P09-D9F0-D9F0. © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.9.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. Bit device; X, Y, M, S are not used as general word at PLC. However, it is able to use as word in GP/LP. M, S device are able to switch into word UW device binding 16 unit, X, Y device are able to switch into word UW device binding 8 unit.
6 Connectable PLC 6.9.2.
6 Connectable PLC 6.9.2.
6 Connectable PLC Type Mark Range Start End C C246 C250 C C251 C255 Data register D D0 D7999 File register D D1000 D7999 Special register D D8000 D8255 GP/LP inner word memory UW UW0 UW6047 Device Counter present value[32b 1 phase 2count] Counter present value[32b 2 phase 2count] © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.9.2.
6 Connectable PLC Type Mark Range Start End C C251 C255 Data register D D0 D7999 File register D D1000 D7999 Special register D D8000 D8255 GP/LP inner word memory UW UW0 UW6047 Device Counter present value[32b 2 phase 2count] © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.9.2.
6 Connectable PLC Type Mark Range Start End C C251 C255 Data register D D0 D7999 File register D D1000 D7999 Special register D D8000 D8255 GP/LP inner word memory UW UW0 UW6047 Device Counter present value[32b 2 phase 2count] © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.9.2.
6 Connectable PLC Type Mark Range Start End C C246 C250 C C251 C255 Data register D D0 D7999 File register D D1000 D7999 Special register D D8000 D8511 GP/LP inner word memory UW UW0 UW6047 Device Counter present value[32b 1 phase 2count] Counter present value[32b 2 phase 2count] © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.9.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.7.2 Available device’.
6 Connectable PLC 6.10 MITSUBISHI Q series PLC connection GP/LP is able to communicate with MITSUBISHI Q series. 6.10.1 System organization The following table is for system organization of this protocol.
6 Connectable PLC (2) RS-232C: Applied cable (6)C3M5P05-D9F0-D9M0 6.10.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error.
6 Connectable PLC 6.10.2.1 Q00J / Q00 / Q01 Type Bit Word 6.10.2.
6 Connectable PLC 6.10.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.8.2 Available device’.
6 Connectable PLC 6.10.4 MELSEC Q series PLC configuration 6.10.4.1 DX-Developer parameter configuration (1) I/O assignment I/O assignment of parameter configuration is to set the type of various module mounted on base module, I/O signal range, and Q series switch.
6 Connectable PLC (2) Switch setting Switch setting description Switch No.
6 Connectable PLC Transmission speed setting 50 Bit unit B15 to B8 0Fh 14400 Bit unit B15 to B8 06h 300 00h 19200 07h 600 01h 28800 08h 1200 02h 38400 09h 2400 03h 57600 0Ah 4800 04h 115200 0Bh 9600 05h 230400 0Ch Baudrate(bps) Baudrate (bps) If two interfaces connect to correspondence device respectively, the sum of communication speed for both interfaces should be set 115,200bps or less(For QJ71C24N(-R2/R4), 230,400bps or less).
6 Connectable PLC 6.10.5 GP/PLC type configuration in GP Editor 6.10.5.1 Basic Model CPU For using Q00J / Q00 / Q01 CPU, select [MITSUBISHI Q SERIES]–[QBasic_EXT_MC]. 6.10.5.2 High Performance Model CPU For using Q02 / Q02H / Q06H / Q12H / Q25H CPU, select [MITSUBISHI Q SERIES]– [QHighP_EXT_MC]. 228 © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.11 Nais PLC connection GP/LP is able to communicate with Nais FP series. 6.11.1 System organization FP sereis executes RS232C commnication. By Tool Port, it is connected with GP/LP. It executes also RS-422 communication with RS-232/422 converter.
6 Connectable PLC The below is a diagram and pin arrangement for RS-232C cable. It is able to connect with GP/LP with Tool Port or COM Port of PLC. (1) When using Tool Port (Applied cable : (11)C3M5P10-D9F0-M5M0) (2) When using COM Port (Applied cable : (12)C3M5P11-D9F0-W4*0) 6.11.1.1 PLC communication configuration(When using Tool Port) PLC communication configuration is available to set or edit from the dedicated ladder program (FPSOFT or FPWIN GR).
6 Connectable PLC (2) When using FPWIN GR 1st After connect the ladder program and PLC, maintain communication status. 2nd Select [Option]-[PLC Configuration] of menu in the ladder software. 3rd ‘PLC Configuration’ dialog box appears. Select ‘Tool Port’ tab. 4th Select as below at the ‘No.414 Baudrate Setting’ item. In case PLC is FP0 series, select ‘9600bps’. In case PLC is FP Sigma series, select ‘19200bps’. 5th Click ‘OK’ and dialog box for downloading appears. Click ‘OK’ and baudrate is changed.
6 Connectable PLC 6.11.1.2 PLC communication configuration(When using COM Port) PLC communication configuration is available to set or edit from the dedicated ladder program (FPSOFT or FPWIN GR). (1) When using FPSOFT 1st After connect the ladder program and PLC, maintain communication status. 2nd Select [Option]-[PLC Configuration] of menu in the ladder software. 3rd ‘PLC Configuration’ dialog box appears. Select ‘Optional port’ in the left Topics box. 4th Select ‘Computer Link’ at the ‘No.
6 Connectable PLC (2) When using FPWIN GR 1st After connect the ladder program and PLC, maintain communication status. 2nd Select [Option]-[PLC Configuration] of menu in the ladder software. 3rd ‘PLC Configuration’ dialog box appears. Select ‘COM1 Port’ tab. 4th Select ‘Computer Link’ at the ‘No.412 Comm. Mode’. 5th Select as below at the ‘No.414 Baudrate’ item. In case PLC is FP0 series, select ‘9600bps’. In case PLC is FP Sigma series, select ‘19200bps’.
6 Connectable PLC 6.11.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.2.
6 Connectable PLC 6.11.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.9.2 Available device’.
6 Connectable PLC 6.12 OMRON SYSMAC C PLC connection GP/LP is able to communicate with Omron SYSMAC C series. 6.12.1 System organization SYSMAC C sereis executes RS232C commnication with GP/LP by Tool Port. It executes also RS-422 communication with RS-232/422 converter. PLC type SYSMAC C CPM1A Communication method RS232C Communication type CPU direct(Loader) Baudrate (bps) 9600 PLC communication configuration for baudrate is set from the dedicated ladder program (CXProgrammer).
6 Connectable PLC 6.12.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error.
6 Connectable PLC 6.12.2.
6 Connectable PLC 6.12.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.10.2 Available device’.
6 Connectable PLC 6.13 OMRON temperature controller connection GP/LP is able to communicate with Omron temperature controller E5XX series. 6.13.1 System organization Omron E5XX sereis executes RS485 commnication. It executes also RS232C commnication with RS485/232 converter. E5AN and E5EN support RS232C communication without converter depending on the model.
6 Connectable PLC 6.13.2 Communication configuration The below table is for communication configuration of Omron E5XX series with GP/LP. No. 1 2 3 4 Item Communication Description Note Modbus RTU mode Baudrate 9600 bps Data type Station Fixed Data length 8 bit Fixed Parity NONE Fixed Stop bit 1 bit Fixed 0 to 31 Selectable (1) Omron E5XX series communication configuration Designate communication configuration for Omron E5XX series.
6 Connectable PLC (2) GP/LP communication configuration As above configuration, GP/LP also should be set for the station as below. 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [SET ENVIRONMENT]-[PLC SETTING]. 3rd Touch CH1 station, station input key pad appears. Enter the same station of the station which is set from E5XX series. Touch ‘ENT’ to save the station and touch ‘Menu’ or ‘Exit’ to exit system setting meun.
6 Connectable PLC 6.13.3 Available device UB device is asGP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error. Be sure to use only within user area UW30 to UW2047 (when not using recipe, UW30 to UW6047). For further information of GP/LP inner memory, refer to ‘3.6 System signal’.
6 Connectable PLC Command value (DEC) 00513 Executing operation Target value 2 00515 Target value 3 00768 Stops AT AT 01024 Executes AT Write mode 01025 Preserves RAM DATA 01536 Soft reset Soft reset 01792 Executes setting area 1 Executes setting area 1 02048 Executes protect level Executes protect level 02305 02816 Initializes setting value 02817 04352 Starts program 04353 is STOP Write mode RAM Preserves RAM DATA AUTO/ MANUAL Available when it Backup write mode 01280 0230
6 Connectable PLC 6.14 SIEMENS S7 series connection GP/LP is able to communicate with SIEMENS S7 series. 6.14.1 System organization SIEMENS S7-200 uses PPI(Point to point interface) communication of SIEMENS and SIEMENS S7-300 uses MPI(Mutil point interface) communication of SIEMENS. It executes RS232C communication with dedicated cable of SIEMENS. It executes also RS-422 communication with RS-232/422 converter.
6 Connectable PLC 6.14.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error.
6 Connectable PLC 6.14.2.
6 Connectable PLC (3) CPU 224 type Type Bit Word I Range Start I0 End I157 Output relay Q Q0 Q157 Inner relay V V0 V81917 Auxiliary relay M M0 M317 Special relay SM SM0 SM5497 Timer contact T T0 T255 Counter contact C C0 C255 GP/LP inner bit memory UB UB0 UB6047F Input register IW IW0 IW14 Output register QW QW0 QW14 Inner register VW VW0 VW8190 Auxiliary register MW MW0 MW30 Special register SM SM0 SM548 Timer present value T T0 T255 Counter presen
6 Connectable PLC 6.14.2.
6 Connectable PLC (4) CPU 313C-2 type Type Bit Word I Range Start I0 End I20477 Output relay Q Q0 Q20477 Auxiliary relay M M0 M2557 GP/LP INNER BIT MEMORY UB UB0 UB6047F Input register IW IW0 IW2046 Output register QW QW0 QW2046 Auxiliary register MW MW0 MW254 GP/LP INNER WORD MEMORY UW UW0 UW6047 End I10237 Device Mark Input relay (5) CPU 314 type Type Bit Word Device Mark Input relay I Range Start I0 Output relay Q Q0 Q10237 Auxiliary relay M M0 M2557
6 Connectable PLC (7) CPU 315-2 type Type Bit Word I Range Start I0 End I20477 Output relay Q Q0 Q20477 Auxiliary relay M M0 M20477 GP/LP INNER BIT MEMORY UB UB0 UB6047F Input register IW IW0 IW2046 Output register QW QW0 QW2046 Auxiliary register MW MW0 MW2046 GP/LP INNER WORD MEMORY UW UW0 UW6047 End I81917 Device Mark Input relay (8) CPU 317-2 type Type Bit Word Device Mark Input relay I Range Start I0 Output relay Q Q0 Q81917 Auxiliary relay M M0 M40
6 Connectable PLC 6.14.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.12.2 Available device’.
6 Connectable PLC 6.15 Allen Bradley MicroLogix series connection GP/LP is able to communicate with Allen-Bradley MicroLogix series. 6.15.1 System organization Allen-Bradley MicroLogix sereis executes RS232C commnication. If PLC has imbeded RS422 loader port or you use RS232/422 converter, RS422 communication is also available.
6 Connectable PLC 6.15.2 Available device Device range is different depending on PLC model. Even though same type PLC, there is difference according to the number of I/O contact point. UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error.
6 Connectable PLC 6.15.2.
6 Connectable PLC 6.15.2.2 MicroLogix 1200 Type Bit Word 6.15.2.
6 Connectable PLC 6.15.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.13.2 Available device’.
6 Connectable PLC 6.16 KONICS Product connection GP/LP is able to communicate with KONICS digital power thyristor unit DPU series and recorder KRN50. 6.16.1 System organization KONICS DPU sereis executes RS485 commnication and it executes also RS232C communication with RS232/422 converter. DPU Communication method RS485 KRN50 RS485 Controller type Communication type CPU direct(Loader) CPU direct(Loader) Wire as below for communicating GP/LP and RS485.
6 Connectable PLC The below table is for communication configuration of recorder KRN50 with GP/LP. No 1 2 3 4 Item Communication mode Baudrate Data type Station Description Note Modbus RTU 9600 bps (Default value of KRN50) Selectable Data length 8bit Selectable Parity None Selectable Stop bit 2bit Selectable 0 to 31 Selectable As above configuration, GP/LP also should be set for the station as below. (1) KONICS DPU series 1st Enter system setting menu.
6 Connectable PLC 6.16.2 Available device UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error. Be sure to use only within user area UW30 to UW2047 (when not using recipe, UW30 to UW6047). For further information of GP/LP inner memory, refer to ‘3.6 System signal’.
6 Connectable PLC Device Description DP30112 Model name8 Enable read/write Read DP30113 Model name9 Read DP30114 Model name10 Read DP30115 Reserved Read DP30116 Reserved Read DP30117 Reserved Read DP30118 Reserved Read DP30118 Coil start address Read DP30119 Coil quantity Read DP30120 Input start address Read DP30121 Input quantity Read DP30122 Holding REG start address Read DP30123 Holding REG quantity Read DP30124 Input REG start address Read DP30125 Input REG
6 Connectable PLC Device Description DP40023 Control integer KP value Enable read/write Read/Write DP40024 Control integer KI value Read/Write DP40025 Output control mode Read/Write DP40026 Event input 1 mode Read/Write DP40027 Event input 2 mode Read/Write DP40028 Event input 3 mode Read/Write DP40029 Auto ref input selector Read/Write DP40030 direction Read/Write DP40031 Operation status 0x000 Read/Write DP40032 Output gradient setting (%) Read/Write DP40033 When input is
6 Connectable PLC (2) Modbus TYPE A (DPU_Mod_A) Type Device Mark Range Start Start Bit GP/LP inner bit memory UB UB0 UB6047F Word device area 3 300001 300005 Word device area 3 300101 300125 Word device area 4 400001 400043 GP/LP inner word memory UW UW0 UW6047 Word Device Description 300001 Output voltage Enable read/write Read 300002 Load current Read 300003 Electric power Read 300004 Load resistance Read 300005 Power frequency Read 300101 Product number H Re
6 Connectable PLC 272 Device Description 300125 Input REG quantity Enable read/write Read Device Description 400001 Reference value Enable read/write Read/Write 400002 Start time Read/Write 400003 Start limit Read/Write 400004 Soft start time Read/Write 400005 Output high limit Read/Write 400006 Output low limit Read/Write 400007 Remote Sp1 value Read/Write 400008 Remote Sp2 value Read/Write 400009 Remote Sp3 value Read/Write 400010 Remote Sp4 value Read/Write 400011
6 Connectable PLC 6.16.2.
6 Connectable PLC Device KR30003 KR30004 Description CH2-present value(PV) CH2 Bit position Read Unit 15 to 10 Read Unit group 9 to 4 Read Status 3 to 2 Read 1 to 0 Read Decimal point position of display value 274 Enable read/write Read KR30101 Serial No H Read KR30102 Serial No L Read KR30103 Software version Read KR30104 Hardware version Read KR30105 Model name1 Read KR30106 Model name2 Read KR30107 Model name3 Read KR30108 Model name4 Read KR30109 Model name5
6 Connectable PLC Device KR40055 Description Hour Enable read/write Read/Write KR40056 Minute Read/Write KR40057 Second Read/Write DP40013 Slow up time Read/Write DP40014 Slow stop time Read/Write DP40015 CL value Read/Write DP40016 OC value Read/Write DP40017 OC time Read/Write DP40018 OV value Read/Write DP40019 OV time Read/Write KR40066 Lock setting Read/Write KR40067 Backlight turn ON method Read/Write KR40070 Using reserved record function or not Read/Write KR40
6 Connectable PLC Device KR40117 Description CH2 alarm output 2 high limit setting value Enable read/write Read/Write KR40118 CH2 alarm output hysteresis Read/Write KR42001 to 16 User unit font0 Read/Write KR42017 to 32 User unit font1 Read/Write KR42033 to 48 User unit font2 Read/Write KR42049 to 64 User unit font3 Read/Write KR42065 to 80 User unit font4 Read/Write KR42081 to 96 User unit font5 Read/Write KR42097 to 112 User unit font6 Read/Write User unit font7 Read/Write Us
6 Connectable PLC Device KR40328 Description CH2 high limit scale display value Enable read/write Read/Write KR40329 CH1 decimal point position of scale Read/Write KR40330 CH2 record display unit Read/Write KR40331 CH2 input correction Read/Write CH2 CH name Read/Write KR40332 to 40333 KR50001 to 52048 User logo (2) Modbus TYPE A (KRN50_Mod_A) Device Description 000001 Starts/Stops record Enable read/write Read/Write 000002 At power ON, starts/stops record Read/Write 000003 When recor
6 Connectable PLC Device 300004 Description CH2 Bit position Enable read/write Read Unit 15 to 10 Read Unit group 9 to 4 Read Status 3 to 2 Read 1 to 0 Read Decimal point position of display value 278 300101 Serial No H Read 300102 Serial No L Read 300103 Software Version Read 300104 Hardware Version Read 300105 Model Name1 Read 300106 Model Name2 Read 300107 Model Name3 Read 300108 Model Name4 Read 300109 Model Name5 Read 300110 Model Name6 Read 300111 Mode
6 Connectable PLC Device 400056 Description Minute Enable read/write Read/Write 400057 Second Read/Write 400066 Lock setting Read/Write 400067 Backlight turn ON method Read/Write 400070 Using reserved record function or not Read/Write 400071 Record start hour Read/Write 400072 Record start minute Read/Write 400073 Record end hour Read/Write 400074 Record end minute Read/Write 400080 Record mode Read/Write 400081 Record speed Read/Write 400082 Digital memo cycle Read/Write
6 Connectable PLC Device 402049 to Description Enable read/write User unit font3 Read/Write User unit font4 Read/Write User unit font5 Read/Write User unit font6 Read/Write User unit font7 Read/Write User unit font8 Read/Write User unit font9 Read/Write 400301 CH1 use/recording or not Read/Write 400302 CH1 input specification Read/Write 400303 CH1 temperature unit Read/Write 400304 CH1 graph low limit scale value Read/Write 400305 CH1 graph high limit scale value Read/Write
6 Connectable PLC Device 400329 Description CH1 decimal point position of scale Enable read/write Read/Write 400330 CH2 record display unit Read/Write 400331 CH2 input correction Read/Write CH2 CH name Read/Write 400332 to 400333 450001 to 452048 User Logo © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.16.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.14.2 Available device’. 6.16.3.
6 Connectable PLC 6.17 DELTA temperature controller connection GP/LP is able to communicate with DELTA temperature controller DTB series. 6.17.1 System organization DELTA DTB series executes RS485 commnication. and it executes also RS232C communication with RS232/422 converter.
6 Connectable PLC As above configuration, GP/LP also should be set for the station as below. 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [SET ENVIRONMENT]-[PLC SETTING]. 3rd Touch CH1 station, station input key pad appears. Enter the same station of the station which is set from DTB series. 4th Touch ‘ENT’ to save the station and touch ‘Menu’ or ‘Exit’ to exit system setting meun. 284 © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.17.2 Available device UB device is as GP/LP inner bit memory, only in GP/LP it is able to use same as general inner device of PLC. It is able to switch into word UW device binding 16 units. However it is related with functional area and it may cause serious error. Be sure to use only within user area UW30 to UW2047 (when not using recipe, UW30 to UW6047). For further information of GP/LP inner memory, refer to ‘3.6 System signal’.
6 Connectable PLC Device M816 M817 M818 Command value 0 1 Command description Temporarily STOP Setting Excuting operation Note RUN Default STOP 0 Valve feedback Feedback 1 Setting Status Feedback Function 0 Auto-tuning Valve feedback Stop AT 1 Status Start AT Default Default (2) Modbus TYPE A(DTB_Mod_A) Type Bit Word Device 100810 100811 100812 100813 100814 100815 100816 100817 100818 6.17.
6 Connectable PLC The following is avilable device list of this menu, and available range is same as ‘6.15.2 Available device’. (1) Modbus Type Mark Bit Word Device M Bit device area UB GP/LP inner bit memory D Word device area UW GP/LP inner word memory Note 16bit (2) Modbus TYPE A Type Bit Word Mark Device 1 Bit device area UB GP/LP inner bit memory 4 Word device area UW GP/LP inner word memory © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.18 DANFOS FC Series GP/LP is able to communicate with FC200 of DANFOS. 6.18.1 System organization DANFOS FC200 executes RS485 communication and it executes also RS232C communication with RS485/232 converter. Controller type DANFOS FC200 Communication method RS485 Communication type CPU direct (Loader) RS-485 communication with GP/LP (Applied cable: (15) C3M5P03-D9M0-T4Y0) The below table is for communication configuration of DANFOS FC200 with GP/LP.
6 Connectable PLC As above configuration, GP/LP also should be set for the station as below. 1st Enter system setting menu. Touch left-upper point as default position of system setting menu. 2nd Select [Environment]-[Serial Communication] and check that the protocol is downloaded. 3rd Touch ‘BEFORE’ or ‘CLOSE’ to exit system setting menu. © Copyright Reserved Autonics Co., Ltd.
6 Connectable PLC 6.18.2 Available device Available deivice of DANFOS FC200 and displayable parameter are as below. Type Bit Word 6.18.
6 Connectable PLC 6.19 Modbus Master GP/LP supports Modbus Master function and is able to connect with other Modbus Slave devices. 6.19.1 System organization Modbus Master protocol is available to communicate with all product which supports Modbus. Communication configuration of Modbus Master protocol should be synchronized with to be connected product’s communication configuration.
6 Connectable PLC 6.19.2 Available device Available devcie of Modbus Master and displayable parameter are as below. Type Bit Word 0 Range Start 000001 End 065536 Bit device area 1 100001 165536 GP/LP inner bit memory UB UB0 UB6047F Word device area 3 300001 365536 Word device area 4 400001 465536 GP/LP inner bit memory UW UW0 UW6047 Device Mark Bit device area Device address is for Modbus Master protocol is 1 based protocol address(Start address: 1).
6 Connectable PLC 6.19.3 Monitorable device in GP/LP GP/LP is able to monitor PLC device and change the status. Enter system setting menu of GP/LP and select [Monitoring]-[Device Monitor]-[DEVICE]. Select to be monitored device and you can change the status. The following is avilable device list of this menu, and available range is same as ‘6.17.2 Available device’.
6 Connectable PLC 294 © Copyright Reserved Autonics Co., Ltd.
MTA-GPLPC1-V1.