Specifications
Table Of Contents
- Title
- Safety Information
- Symbols used in the manual
- Table of Contents
- 1 Introduction
- 2 Profibus DP
- 3 CC-Link
- 4 Ethernet
- A Appendix
- Index

Ethernet Head Station STL-ETH1 (Ethernet)
4 - 14
MITSUBISHI ELECTRIC
● SSI interface module
The SSI Interface module has a total of 4 bytes of user data in the Input Process Image, which has
2 words mapped into the image. Word alignment is applied.
Type of module Name ID number Description
Process Image [Byte]
Input Output
Interface module STL-SSI 51205057 Input module for SSI encoder 4 0
Tab. 4-23: Process data of the interface module STL-SSI
Input Process Image
Description
Offset
Byte Destination
High Byte Low Byte
0 D1 D0
Data bytes
1 D3 D2
Tab. 4-24: Allocation of data for the SSI interface module STL-SSI