Specifications
II Parameters
User Parameters
II - 11
【#8205】 OT-CHECK-P
Set the coordinates of the (+) direction in the movable range of the stored stroke limit II or
the upper limit coordinates of the prohibited range of stored stroke limit IIB.
---Setting range---
-99999.999 to 99999.999 (mm)
【#8206】 TOOL CHG. P
Set the coordinates of the tool change position for G30. n (tool change position return).
Set with coordinates in the basic machine coordinate system.
---Setting range---
-99999.999 to 99999.999 (mm)
【#8207】 G76/87 IGNR (for M system only)
Select whether to enable the shift operation at G76 (fine boring) and G87 (back boring).
0: Enable
1: Disable
【#8208】 G76/87 (-) (for M system only)
Select the shift direction at G76 and G87.
0: Shift to (+) direction
1: Shift to (-) direction
【#8209】 G60 SHIFT (for M system only)
Set the last positioning direction and distance for a G60 (unidirectional positioning)
command.
---Setting range---
-99999.999 to 99999.999 (mm)
【#8210】 OT INSIDE
Select whether the stored stoke limit function set by #8204 and #8205 prevents the machine
from moving to the inside or outside of the specified range.
0: Inhibits outside area (Select stored stroke limit II.)
1: Inhibits inside area (Select stored stroke limit II B.)
【#8211】 MIRR. IMAGE
Select whether to enable the parameter mirror image function.
0: Disable
1: Enable
【#8213(PR)】 Rotation axis type
Select the rotation type (short-cut valid/invalid) or linear type (workpiece coordinate linear
type/all coordinate linear type).
This parameter is enabled only when "#1017 rot" is set to "1". (Note)
0: Short-cut invalid
1: Short-cut valid
2: Workpiece coordinate linear type
3: All coordinate linear type
(Note) The movement method is as follows by the specified rotation axis type.
<Workpiece coordinate value>
0,1 : Display range 0° to 359.999°
2,3 : Display range 0° to ± 99999.999°
<Machine coordinate value/relative position>
0,1,2 : Display range 0° to 359.999°
3 : Display range 0° to ± 99999.999°
<ABS command>
0 : The incremental amount from the end point to the current position is divided by
360, and the axis moves by the remainder amount according to the sign.
1 : Moves with a short-cut to the end point.
2,3 : In the same manner as the normal linear axis, moves according to the sign by
the amount obtained by subtracting the current position from the end point.
<INC command>
0,1,2,3 : Moves in the direction of the commanded sign by the commanded
incremental amount starting at the current position.
<Reference position return>
0,1,2 : The movement to the middle point applies to the ABS command or the INC
command.
Returns with movement within 360 degrees from the middle point to reference
position.
3 : The movement to the middle point applies to the ABS command or the INC
command.
Moves and returns in the reference position direction for the difference from the
current position to the reference position.
【#8215】 TLM std length
Set the TLM standard length.
TLM standard length is the distance from a tool replacement point (reference position) to
the measurement basic point (surface) which is used to measure the tool length.
(The same value as "#2016 tlml+" will be reflected. When either setting changes, the other
will change accordingly.)
---Setting range---
-99999.999 to 99999.999 (mm)