Specifications
II Parameters
User Parameters
II - 4
【#8021】 COMP_CHANGE
Select whether to share or separate the compensation coefficient at the corner/curve during
the high-accuracy control mode.
0: Share ("#8019 R COMP" is applied.)
1: Separate
- Corner : #8022 CORNER COMP
- Curve : #8023 CURVE COMP
(Note) Set "1" when using SSS control.
【#8022】 CORNER COMP
Set the compensation coefficient to further reduce or increase the roundness at the corner
during the high-accuracy control mode.
Coefficient = 100 - setting value
(Note) This is valid when "#8021 COMP CHANGE" is set to "1".
Reference to "#8020 Corner decreasing speed "for theoretical corner roundness amount,
corner decreasing speed, theoretical 90 degree dull amount, 90 degree corner decreasing
speed.
---Setting range---
-1000 to 99 (%)
【#8023】 CURVE COMP
Set the compensation coefficient to further reduce or increase the radius reduction amount
at the curve (arc, involute, spline) during the high-accuracy control mode.
Coefficient = 100 - setting value
(Note) This is valid when "#8021 COMP CHANGE" is set to "1".
For theoretical radius reduction error amount, R5mm arc deceleration speed and R1mm arc
deceleration speed, refer to "#8019 R COMP".
---Setting range---
-1000 to 99 (%)
【#8025】 SPLINE ON (for M system only)
Select whether to enable the spline function.
0: Disable
1: Enable
Spline interpolation is valid during G61.2 modal, regardless of this setting.
【#8026】 CANCEL ANG. (for M system only)
Set the angle where the spline interpolation is temporarily canceled.
When the angle made by blocks exceeds this parameter setting value, spline interpolation
will be canceled temporarily. In consideration of the pick feed, set a value a little smaller
than the pick feed angle.
---Setting range---
0 to 180 (°)
0: 180 (°)
【#8027】 Toler-1 (for M system only)
Set the maximum chord error (tolerance) in a block that includes an inflection point. Set the
tolerance applicable when the applicable block is developed to fine segments by CAM.
(normally about 10 μm)
When "0.000" is set, the applicable block will be linear.
---Setting range---
0.000 to 100.000 (mm)
【#8028】 Toler-2 (for M system only)
Set the maximum chord error (tolerance) in a block that includes no inflection point. Set the
tolerance applicable when the applicable block is developed to fine segments by CAM.
(normally about 10 μm)
When "0.000" is set, the applicable block will be linear.
---Setting range---
0.000 to 100.000 (mm)
【#8029】 FairingL (for M system only)
Set the length of the block subject to fairing.
(Enabled when "#8033 Fairing ON" is set to "1".)
---Setting range---
0 to 100.000 (mm)
【#8030】 MINUTE LENGS (for M system only)
Set the fine-segment length where the spline interpolation is temporarily canceled.
When the length of one block exceeds this parameter setting value, spline interpolation is
canceled temporarily and linear interpolation is performed. Set a value a little smaller than
one block length of the program.
If "-1" is set, spline interpolation will be performed regardless of block length.
---Setting range---
-1 to 127 (mm)
0: 1 (mm)