Specifications

II Parameters
User Parameters
II - 1
1. User Parameters
The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF and
ON to enable the parameter settings.
(Note) This parameter description is common for M700V/M70V/E70 Series.
It is written on the assumption that all option functions are added.
Confirm with the specifications issued by the machine tool builder before starting use.
#8001 WRK COUNT M
Set the M code for counting the number of the workpiece repeated machining.
The number of the M-codes set by this parameter is counted.
The No. will not be counted when set to "0".
---Setting range---
0 to 999
#8002 WRK COUNT
Set the initial value of the number of workpiece machining. The number of current
workpiece machining is displayed.
---Setting range---
0 to 999999
#8003 WRK COUNT LIMIT
Set the maximum number of workpiece machining.
A signal will be output to PLC when the number of machining times is counted to this limit.
---Setting range---
0 to 999999
#8004 SPEED
Set the feedrate during automatic tool length measurement.
---Setting range---
1 to 1000000 (mm/min)
#8005 ZONE r
Set the distance between the measurement point and deceleration start point.
---Setting range---
0 to 99999.999 (mm)
#8006 ZONE d
Set the tolerable range of the measurement point.
An alarm will occur when the sensor signal turns ON before the range, set by this
parameter, has not been reached from the measurement point, or when the signal does not
turn ON after the range is passed.
---Setting range---
0 to 99999.999 (mm)
#8007 OVERRIDE
Set the override value for automatic corner override.
---Setting range---
0 to 100 (%)
#8008 MAX ANGLE
Set the maximum corner opening angle where deceleration should start automatically.
When the angle is larger than this value, deceleration will not start.
---Setting range---
0 to 180 (°)
#8009 DSC. ZONE
Set the position where deceleration starts at the corner.
Designate at which length point before the corner deceleration should start.
---Setting range---
0 to 99999.999 (mm)
#8010 ABS. MAX. (for L system only)
Set the maximum value when inputting the tool wear compensation amount.
A value exceeding this setting value cannot be set.
Absolute value of the input value is set.
(If a negative value is input, it is treated and set as a positive value.)
If "0" is input, this parameter will be disabled.
---Setting range---
0 to 999.999 (mm)
(Input setting increment applies)