Specifications

I Alarms
Program Errors (P)
I - 75
P605 T & TLM command in a block
Details
The T code is in the same block as the automatic tool length measurement block.
Remedy
- Specify the T code before the automatic tool length measurement block.
P606 T cmnd not found before TLM
Details
The T code was not yet specified in automatic tool length measurement.
Remedy
- Specify the T code before the automatic tool length measurement block.
P607 TLM illegal signal
Details
The measurement position arrival signal turned ON before the area specified by the D com-
mand or "#8006 ZONE d". Otherwise, the signal remained OFF to the end.
Remedy
- Correct the program.
P608 Skip during radius compen
Details
A skip command was issued during radius compensation processing.
Remedy
- Issue a radius compensation cancel (G40) command or remove the skip command.
P610 Illegal parameter
Details
- The parameter setting is not correct.
- G114.1 was commanded while the spindle synchronization was selected with the PLC in-
terface signal.
- G110 was commanded while the mixed control (cross axis control) was selected with the
PLC interface signal.
- G125 was commanded while the control axis synchronization across part systems was se-
lected with the PLC interface signal.
- G126 was commanded while the control axis superimposition was selected with the PLC
interface signal.
Remedy
- Correct the settings of "#1514 expLinax (Exponential function interpolation linear axis)" and
"#1515 expRotax (Exponential function interpolation rotary axis)".
- Correct the program.
- Correct the parameter settings.
P611 No spec: Exponential function
Details
There is no specification for the exponential interpolation.
Remedy
- Check the specifications.
P612 Exponential function error
Details
A travel command for exponential interpolation was issued during mirror image for facing tool
posts.
Remedy
- Correct the program.
P700 Illegal command value
Details
Spindle synchronization was commanded to a spindle that is not connected serially.
Remedy
- Correct the program.
- Correct the parameter settings.
P900 No spec: Normal line control
Details
A normal line control command (G40.1, G41.1, or G42.1) was issued though it is out of spec-
ifications.
Remedy
- Check the specifications.
P901 Normal line control axis G92
Details
A coordinate system preset command (G92) was issued to a normal line control axis during
normal line control.
Remedy
- Correct the program.
P902 Normal line control axis error
Details
- The normal line control axis was set to a linear axis.
- The normal line control axis was set to the linear type rotary axis II axis.
- The normal line control axis has not been set.
- The normal line control axis is the same as the plane selection axis.
Remedy
- Correct the normal line control axis setting.
P903 Plane chg in Normal line ctrl
Details
The plane selection command (G17, G18, or G19) was issued during normal line control.
Remedy
- Delete the plane selection command (G17, G18, or G19) from the program of the normal
line control.
P920 No spec: 3D coord conv
Details
There is no specification for 3-dimensional coordinate conversion.
Remedy
- Check the specifications.