Program Errors (P)
I - 65
P174 No spec:Comp input by prog G11
Details
Compensation data input by program cancel (G11) was commanded though there is no spec-
ification of compensation data input by program.
Remedy
- Check the specifications.
P177 Tool life count active
Details
Registration of tool life management data with G10 was attempted when the "usage data
count valid" signal was ON.
Remedy
- The tool life management data cannot be registered during the usage data count. Turn the
"usage data count valid" signal OFF.
P178 Tool life data entry over
Details
The number of registration groups, total number of registered tools or the number of registra-
tions per group exceeded the range in the specifications.
Remedy
- Correct the number of registrations.
P179 Illegal group No.
Details
- A duplicate group No. was found at the registration of the tool life management data with
G10.
- A group No. that was not registered was designated during the T****99 command.
- An M code command, which must be issued as a single command, coexists in the same
block as that of another M code command.
- The M code commands set in the same group exist in the same block.
Remedy
- Register the tool life data once for one group: commanding with a duplicate group No. is not
allowed.
- Correct to the group No.
P180 No spec: Drilling cycle
Details
A fixed cycle command (G72 - G89) was issued though it is out of specifications.
Remedy
- Check the specifications.
- Correct the program.
P181 No spindle command (Tap cycle)
Details
Spindle rotation speed (S) has not been commanded in synchronous tapping.
Remedy
- Command the spindle rotation speed (S) in synchronous tapping.
- When "#8125 Check Scode in G84" is set to "1", enter the S command in the same block
where the synchronous tapping command is issued.
P182 Synchronous tap error
Details
- Connection to the main spindle unit was not established.
- The synchronous tapping was attempted with the spindle not serially connected under the
multiple-spindle control I.
Remedy
- Check connection to the main spindle.
- Check that the main spindle encoder exists.
- Set 1 to the parameter #3024 (sout).
P183 No pitch/thread number
Details
The pitch or number of threads has not been commanded in the tap cycle of a fixed cycle for
drilling command.
Remedy
- Specify the pitch data and the number of threads by F or E command.
P184 Pitch/thread number error
Details
- The pitch or the number of threads per inch is illegal in the tap cycle of the fixed cycle for
drilling command.
- The pitch is too small for the spindle rotation speed.
- The thread number is too large for the spindle rotation speed.
Remedy
- Correct the pitch or the number of threads per inch.
P185 No spec: Sync tapping cycle
Details
Synchronous tapping cycle (G84/G74) was commanded though it is out of specifications.
Remedy
- Check the specifications.
P186 Illegal S cmnd in synchro tap
Details
S command was issued during synchronous tapping modal.
Remedy
- Cancel the synchronous tapping before issuing the S command.
P190 No spec: Turning cycle
Details
A lathe cutting cycle command was issued though it is out of specifications.
Remedy
- Check the specification.
- Delete the lathe cutting cycle command.