Specifications
I Alarms
Program Errors (P)
I - 59
13. Program Errors (P)
P10 No. of simultaneous axes over
Details
The number of axis addresses commanded in a block is exceeds the specifications.
Remedy
- Divide the alarm block command into two.
- Check the specifications.
P11 Illegal axis address
Details
The axis address commanded by the program does not match any of the ones set by the pa-
rameter.
Remedy
- Correct the axis names in the program.
P20 Division error
Details
The issued axis command cannot be divided by the command unit.
Remedy
- Correct the program.
P29 Not accept command
Details
The command has been issued when it is impossible.
- The normal line control command (G40.1, G41.1, G42.1) has been issued during the modal
in which the normal line control is not acceptable.
- The command has been issued during the modal in which the 2-part system synchronous
thread cutting is not acceptable.
Remedy
- Correct the program.
P30 Parity H error
Details
The number of holes per character on the paper tape is even for EIA code and odd for ISO
code.
Remedy
- Check the paper tape.
- Check the tape puncher and tape reader.
P31 Parity V error
Details
The number of characters per block on the paper tape is odd.
Remedy
- Make the number of characters per block on the paper tape even.
- Set the parameter parity V selection OFF.
P32 Illegal address
Details
An address not listed in the specifications has been used.
Remedy
- Correct the program address.
- Correct the parameter settings.
- Check the specifications.
P33 Format error
Details
The command format in the program is not correct.
Remedy
- Correct the program.
P34 Illegal G code
Details
The commanded G code is not in the specifications.
An illegal G code was commanded during the coordinate rotation command.
Remedy
- Correct the G code address in the program.
Details
G51.2 or G50.2 was commanded when "#1501 polyax (Rotational tool axis number)" was set
to "0".
G51.2 or G50.2 was commanded when the tool axis was set to the linear axis ("#1017 rot (Ro-
tational axis)" is set to"0").
Remedy
- Correct the parameter settings.
P35 Setting value range over
Details
The setting range for the addresses has been exceeded.
Remedy
- Correct the program.
P36 Program end error
Details
"EOR" has been read during tape and memory mode.
Remedy
- Enter the M02 and M30 command at the end of the program.
- Enter the M99 command at the end of the subprogram.
P37 O, N number zero
Details
"0" has been specified for program or sequence No.
Remedy
- Designate program Nos. within a range from 1 to 99999999.
- Designate sequence Nos. within a range from 1 to 99999.