Specifications

I Alarms
MCP Alarms (Y)
I - 37
Y51 Values of PC1/PC2 too large 0101
Details
The PC1 and PC2 settings for the rotary axis are too large.
Remedy
Correct "#2201 SV001 PC1 (Motor side gear ratio)" and "#2202 SV002 PC2 (Machine side
gear ratio)".
Y90 No spindle signal 0001-0007
Details
There is an error in the spindle encoder signal.
The data transmission to the drive unit is stopped when this error occurs.
Remedy
Check the spindle encoder's feedback cable and the encoder.