Specifications

II Parameters
PLC Axis Indexing Parameters
II - 248
#12864 aux_stpos16 Station 16 coordinate
Set the station 16 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12865 aux_stpos17 Station 17 coordinate
Set the station 17 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12866 aux_stpos18 Station 18 coordinate
Set the station 18 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12867 aux_stpos19 Station 19 coordinate
Set the station 19 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12868 aux_stpos20 Station 20 coordinate
Set the station 20 coordinate value when arbitrary coordinate assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
---Setting range---
-99999.999 to 99999.999(° or mm)
#12870 aux_PSWcheck PSW detection method
Select the criterion for the output of position switches 1 to 15.
bit0 to E correspond to position switches 1 to 15.
0: Judged by the machine position of the command system.
1: Judged by the machine FB position (actual position).
(Note) The bits that are not explained here must be set to "0".
#12871 aux_PSW1dog1 PSW1 area setting 1
Set "PSW1 area setting" 1 and 2 to specify the area where the position switch 1 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12872 aux_PSW1dog2 PSW1 area setting 2
Set "PSW1 area setting" 1 and 2 to specify the area where the position switch 1 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12873 aux_PSW2dog1 PSW2 area setting 1
Set "PSW2 area setting" 1 and 2 to specify the area where the position switch 2 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12874 aux_PSW2dog2 PSW2 area setting 2
Set "PSW2 area setting" 1 and 2 to specify the area where the position switch 2 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
#12875 aux_PSW3dog1 PSW3 area setting 1
Set "PSW3 area setting" 1 and 2 to specify the area where the position switch 3 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)