Specifications

II Parameters
PLC Axis Indexing Parameters
II - 245
16. PLC Axis Indexing Parameters
(Note) This parameter description is common for M700V/M70V/E70 Series.
It is written on the assumption that all option functions are added.
Confirm with the specifications issued by the machine tool builder before starting use.
#12800(PR) chgauxno Auxiliary axis number
Set the axis No. to be controlled as auxiliary axis using auxiliary axis interface.
When "0" is set, the axis will not operate as auxiliary axis.
---Setting range---
M730/M750/M730VS/M750VS/M730VW/M750VW: 0 to 6
M720/M720VS/M720VW/M70 Series/M70V Series: 0 to 4
E70 Series: 0 to 1
#12801(PR) aux_station Number of indexing stations
Set the number of stations.
For linear axis, this value is expressed by: number of divisions = number of stations -1.
Setting "0" or "1" sets the number of stations to 2.
---Setting range---
0 to 360
#12802(PR) aux_Cont1 Control parameter 1
The bits that are not explained here must be set to "0".
Bit3:
0: Automatic reach signal isn't interlocked with the start signal.
1: Automatic reach signal is interlocked with the start signal.
Bit4:
0: Automatic reach signal is turned ON again.
1: Automatic reach signal isn't turned ON again.
Bit5:
0: Station No. Output within fixed position.
1: Station No. Constantly output.
bit9:
0: Rotation direction determined by operation control signal (DIR)
1: Rotation direction in the shortcut direction
bitE:
0: Rotation direction in operation control signal (DIR) or in the shortcut direction
1: Rotation direction in the arbitrary position command sign direction
bitF:
0: Stopper direction is in the positioning direction.
1: Stopper direction is in the sign direction of the stopper amount.
#12803(PR) aux_Cont2 Control parameter 2
The bits that are not explained here must be set to "0".
bit4:
0: Uniform assignment
1: Arbitrary coordinate assignment
#12804(PR) aux_tleng Linear axis stroke length
Set the movement stroke length for linear axes.
(Note 1)Setting "0.000" causes an MCP alarm at the power ON.
(Note 2)This parameter is meaningless at the arbitrary coordinate assignment or with the
arbitrary coordinate designation method.
---Setting range---
0.000 to 99999.999 (mm)
#12805 aux_ST.offset Station offset
Set the distance (offset) from the reference position to station 1.
---Setting range---
-99999.999 to 99999.999 (° or mm)
#12810+10(n-1) aux_Aspeedn Operation parameter group n Automatic operation speed
Set the feedrate during automatic operation when "operation parameter group n" is
selected.
"#12810 aux_Aspeed1" is regarded as the clamp value for the automatic operation speeds
and manual operation speeds of all operation groups.
A speed exceeding "aux_Aspeed1" cannot be commanded, even if it is set in a parameter.
(Note)Setting "0" causes an operation error at the "Operation start" signal's ON.
---Setting range---
0 to 100000 (°/min or mm/min)