Specifications
II Parameters
CC-Link Parameters
II - 241
【#24018+40(n-1)】 SLn RWr dev name Remote register (RWr) refresh device name
Set the refresh device name of the remote register (RWr) to be automatically refreshed.
(Example) W
"n" represents the expansion slot No.(n=1 to 3)
Set "0" when no setting is required.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
0,M,L,B,D,W,R
【#24019+40(n-1)】 SLn RWr dev No. Remote register (RWr) refresh device No.
Set the refresh device No. of the remote register (RWr) to be automatically refreshed.
"n" represents the expansion slot No.(n=1 to 3)
(Note 1) When setting parameters in ALL.PRM with using the parameter input/output
function, input the device No. of decimal digit.
(Example) When setting "X400" for the remote input (RX) refresh device No., input as
follows; #24014+40(n-1): "X" #24015+40(n-1): "1024"
(Note 2) When the refresh device name has been set, the refresh device No. will be
"0".Confirm the refresh device No. after changing the refresh device name.
When specifying a bit device, set the address in increments of 16 points.
The operation will not be guaranteed unless the address is set in increments of 16 points.
(Example) 1FF0
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
M: 0 to 10239
L: 0 to 511
B: 0 to 1FFF
D: 0 to 2047
W: 0 to 1FFF
R: 8300 to 9799, 9800 to 9899
【#24020+40(n-1)】 SLn RWw dev name Remote register (RWw) refresh device name
Set the refresh device name of the remote register (RWw) to be automatically refreshed.
(Example) W
"n" represents the expansion slot No.(n=1 to 3)
Set "0" when no setting is required.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
0,M,L,B,D,W,R
【#24021+40(n-1)】 SLn RWw dev No. Remote register (RWw) refresh device No.
Set the refresh device No. of the remote register (RWw) to be automatically refreshed.
"n" represents the expansion slot No.(n=1 to 3)
(Note 1) When setting parameters in ALL.PRM with using the parameter input/output
function, input the device No. of decimal digit.
(Example) When setting "X400" for the remote input (RX) refresh device No., input as
follows; #24014+40(n-1): "X" #24015+40(n-1): "1024"
(Note 2) When the refresh device name has been set, the refresh device No. will be
"0".Confirm the refresh device No. after changing the refresh device name.
When specifying a bit device, set the address in increments of 16 points.
The operation will not be guaranteed unless the address is set in increments of 16 points.
(Example) 1FF0
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
M: 0 to 10239
L: 0 to 511
B: 0 to 1FFF
D: 0 to 2047
W: 0 to 1FFF
R: 8300 to 9799, 9800 to 9899
【#24022+40(n-1)】 SLn SB dev name Special relay (SB) refresh device name
Set the refresh device name of the special relay (SB) to be automatically refreshed.
(Example) SB
"n" represents the expansion slot No.(n=1 to 3)
Set "0" when no setting is required.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
0,M,L,B,D,W,R,SB