Specifications
II Parameters
CC-Link Parameters
II - 238
15. CC-Link Parameters
(Note) This parameter description is common for M700V/M70V/E70 Series.
It is written on the assumption that all option functions are added.
Confirm with the specifications issued by the machine tool builder before starting use.
【#24001+40(n-1)(PR)】 SLn station No. CC-Link station No.
Set the station No. of the CC-Link I/F unit.
"n" represents the expansion slot No.(n=1 to 3)
-1: Invalid
0: Master station
1 to 64: Slave station
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
-1 to 64
【#24002+40(n-1)(PR)】 SLn line-spd&Mode CC-Link transmission rate and mode
Select the transmission rate and operation mode of the CC-Link I/F unit.
"n" represents the expansion slot No.(n=1 to 3)
<Online mode>
0 : 156Kbps
1 : 625Kbps
2 : 2.5Mbps
3 : 5Mbps
4 : 10M
<Circuit test mode>
5 : 156Kbps
6 : 625Kbps
7 : 2.5Mbps
8 : 5Mbps
9 : 10Mbps
<Hardware test mode>
10 : 156Kbps
11 : 625Kbps
12 : 2.5Mbps
13 : 5Mbps
14 : 10Mbps
(Note) Perform hardware test after removing the CC-Link cable.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set a value within the setting range.
---Setting range---
0 to 14
【#24003+40(n-1)(PR)】 SLn set fault sta Setting of data link faulty station
Select whether to clear or hold the data input from the data link faulty station.
"n" represents the expansion slot No.(n=1 to 3)
0: Clear
1: Hold
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E-
E)" for the details of the functions.
---Master station---
Set to "0" or "1".
---Local/standby master station---
Set to "0" or "1".
【#24004+40(n-1)】 SLn PLC stop set Setting at PLC STOP
Set whether to refresh or compulsorily clear the slave stations at PLC STOP.
"n" represents the expansion slot No.(n=1 to 3)
0: Refresh
1: Compulsorily clear
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E-
E)" for the details of the functions.
---Master station---
Set to "0" or "1".
---Local/standby master station---
Set to "0" or "1".
【#24005+40(n-1)(PR)】 SLn occ stations Number of occupied stations
Set the number of occupied local and standby master stations.
"n" represents the expansion slot No.(n=1 to 3)
---Master station---
Set to "0".
---Local/standby master station---
Set to either of "1" to "4".
---Setting range---
0 to 4