Specifications
II Parameters
Auxiliary Axis Parameters
II - 234
【#50221】 push.t1 Stopper standby time
Set the standby time from the stopper starting coordinate positioning to the stopper
operation start in the stopper positioning.
Default value: 0
---Setting range---
0 to 9999 (ms)
【#50222】 push.t2 Stopper torque release time
Set the time from the completion of the stopper operation to the changeover of the stopper
torque in the stopper positioning.
Default value: 0
---Setting range---
0 to 9999 (ms)
【#50223】 push.t3 Set position signal output delay time
Set the time from the completion of the stopper operation to the output of the “automatic set
position reached” (JSTA), “set position reached” (JST) or “near set position” (NEAR) signal
in the stopper positioning.
Default setting: 0
---Setting range---
0 to 9999 (ms)