Specifications

II Parameters
Auxiliary Axis Parameters
II - 232
#50200 PSWcheck PSW detection method
Select the criterion for the output of position switches 1 to 8.
bit0 to 7 correspond to position switches 1 to 8.
0: Judged by the machine position of the command system.
1: Judged by the machine FB position (actual position).
The bits that are not written here must be set to "0".
#50201 PSW1 dog1 PSW1 area setting 1
Set "PSW1 area setting" 1 and 2 to specify the area where the position switch 1 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50202 PSW1 dog2 PSW1 area setting 2
Set "PSW1 area setting" 1 and 2 to specify the area where the position switch 1 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50203 PSW2 dog1 PSW2 area setting 1
Set "PSW2 area setting" 1 and 2 to specify the area where the position switch 2 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50204 PSW2 dog2 PSW2 area setting 2
Set "PSW2 area setting" 1 and 2 to specify the area where the position switch 2 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50205 PSW3 dog1 PSW3 area setting 1
Set "PSW3 area setting" 1 and 2 to specify the area where the position switch 3 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50206 PSW3 dog2 PSW3 area setting 2
Set "PSW3 area setting" 1 and 2 to specify the area where the position switch 3 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50207 PSW4 dog1 PSW4 area setting 1
Set "PSW4 area setting" 1 and 2 to specify the area where the position switch 4 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50208 PSW4 dog2 PSW4 area setting 2
Set "PSW4 area setting" 1 and 2 to specify the area where the position switch 4 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation. For rotary axes, the output turns ON in the area excluding 0.000
degree.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)