Specifications
II Parameters
Auxiliary Axis Parameters
II - 231
【#50180】 just4 Operation parameter group 4 Set position output width
Set the tolerable value at which "set position reached" (JST) or "automatic set position
reached" (JSTA) signal is output when operation parameter group 4 is selected.
"Set position reached" (JST) indicates that the machine position is at any station. During
automatic operation, "automatic set position reached" (JSTA) is also output under the same
condition. These signals will turn OFF when the machine position moves away from the
station over this value.
Default value: 0.500
---Setting range---
0.000 to 99999.999 (° or mm)
【#50181】 near4 Operation parameter group 4 Near set position output width
Set the tolerable value at which "near set position" (NEAR) signal is output when operation
parameter group 4 is selected.
"Near set position" (NEAR) indicates that the machine position is near any station position.
This value is generally set wider than the set position output width.
During operations, this is related to the special commands when the station selection is set
to "0".
Default value: 1.000
---Setting range---
0.000 to 99999.999 (° or mm)
【#50190】 stpos2 Station 2 coordinate
Set the station 2 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50191】 stpos3 Station 3 coordinate
Set the station 3 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50192】 stpos4 Station 4 coordinate
Set the station 4 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50193】 stpos5 Station 5 coordinate
Set the station 5 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50194】 stpos6 Station 6 coordinate
Set the station 6 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50195】 stpos7 Station 7 coordinate
Set the station 7 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50196】 stpos8 Station 8 coordinate
Set the station 8 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50197】 stpos9 Station 9 coordinate
Set the station 9 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)