Specifications

II Parameters
Auxiliary Axis Parameters
II - 231
#50180 just4 Operation parameter group 4 Set position output width
Set the tolerable value at which "set position reached" (JST) or "automatic set position
reached" (JSTA) signal is output when operation parameter group 4 is selected.
"Set position reached" (JST) indicates that the machine position is at any station. During
automatic operation, "automatic set position reached" (JSTA) is also output under the same
condition. These signals will turn OFF when the machine position moves away from the
station over this value.
Default value: 0.500
---Setting range---
0.000 to 99999.999 (° or mm)
#50181 near4 Operation parameter group 4 Near set position output width
Set the tolerable value at which "near set position" (NEAR) signal is output when operation
parameter group 4 is selected.
"Near set position" (NEAR) indicates that the machine position is near any station position.
This value is generally set wider than the set position output width.
During operations, this is related to the special commands when the station selection is set
to "0".
Default value: 1.000
---Setting range---
0.000 to 99999.999 (° or mm)
#50190 stpos2 Station 2 coordinate
Set the station 2 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50191 stpos3 Station 3 coordinate
Set the station 3 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50192 stpos4 Station 4 coordinate
Set the station 4 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50193 stpos5 Station 5 coordinate
Set the station 5 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50194 stpos6 Station 6 coordinate
Set the station 6 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50195 stpos7 Station 7 coordinate
Set the station 7 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50196 stpos8 Station 8 coordinate
Set the station 8 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
#50197 stpos9 Station 9 coordinate
Set the station 9 coordinate value when non-uniform assignment is selected.
The station 1 coordinate value is fixed at "0.000" (machine coordinate zero point).
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)