Specifications
II Parameters
Auxiliary Axis Parameters
II - 226
【#50104(PR)】 tleng Linear axis stroke length
Set the travel stroke length for linear axis.
The set value for this parameter will be ignored when non-uniform assignments are set or
random positions are commanded.
Default value: 100.000
---Setting range---
0.001 to 99999.999 (mm)
【#50110】 ZRNspeed Reference position return speed
Set the clamp value of the feedrate when a reference position return is carried out.
The feedrate applies the manual operation speed in the parameter group selected at the
time, which is clamped by this parameter set value.
Default value: 1000
---Setting range---
1 to 100000 (°/min or mm/min)
【#50111】 ZRNcreep Reference position return creep speed
Set the approach speed to the reference position after dog detection during a reference
position return.
Default value: 200
---Setting range---
1 to 65535 (°/min or mm/min)
【#50112】 grid mask Grid mask
Set the amount that the dog is artificially extended. Normally set the half amount of the grid
spacing.
Default value: 0
---Setting range---
0 to 65536 (1/1000° or μm)
【#50113(PR)】 grspc Grid spacing
Select the number of divisions in the grid spacing that is the conventional motor rotation
travel amount.
The setting values "1", "2", "3" and "4" divide into 2, 4, 8 and 16 divisions respectively.
Default value: 0
---Setting range---
0 to 4 ("1 / (n-th power of 2)" divisions)
【#50114】 ZRNshift Reference position shift amount
Set the shift amount in a dog-type reference position return from the electrical basic
position, which is determined on the grid, to the reference position.
Default value: 0
---Setting range---
0 to 65536 (1/1000° or μm)
【#50115】 ST. ofset Station offset
Set the distance (offset) from the reference position to station 1.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50116(PR)】 ABS base Absolute position zero point
Set the travel distance in shifting the machine coordinate basic point from the standard point
during absolute position initializing.
Default value: 0.000
---Setting range---
-99999.999 to 99999.999 (° or mm)
【#50117】 Limit(+) Soft limit (+)
Set the upper limit for commands in the plus direction.
Commands in the plus direction beyond this set value are not possible.
If the machine is in a position exceeding the setting value, commands in the minus direction
will be possible.
If "#50117 Limit(+)" and "#50118 Limit(-)" are set to the same value, the soft limit function
will not operate.
Default value: 1.000
---Setting range---
-99999.999 to 99999.999 (mm)
【#50118】 Limit(-) Soft limit (-)
Set the lower limit for commands in the minus direction.
Commands in the minus direction beyond this set value are not possible.
If the machine is in a position exceeding the setting value, commands in the plus direction
will be possible.
Default value: 1.000
---Setting range---
-99999.999 to 99999.999 (mm)