Specifications
II Parameters
Auxiliary Axis Parameters
II - 225
【#50101(PR)】 Cont1 Control parameter 1
The bits that are not explained here must be set to the default value.
Default value : bit9 = “1“, Other bits =”0”
bit1:
0: High-speed zero point return after the establishment of zero point
1: Dog-type return for each reference position return
bit8:
0: Reference position return direction (+)
1: Reference position return direction (-)
bit9:
0: Rotation direction determined by operation control signal (DIR)
1: Rotation direction in the shortcut direction
bitA
0: Machine basic position becomes the basic point.
1: Electrical basic position becomes the basic point.
bitD
0: Creation of coordinate zero point is valid.
1: Zero point is established at power supply ON position.
bitE
0: Rotation direction in operation control signal (DIR) or in the shortcut direction
1: Rotation direction in the arbitrary position command sign direction
bitF
0: Stopper direction is in the positioning direction.
1: Stopper direction is in the sign direction of the stopper amount.
【#50102(PR)】 Cont2 Control parameter 2
The bits that are not explained here must be set to the default value.
Default value : bit1,2,7 = “1“, Other bits =”0”
bit1:
0: Error not corrected at servo OFF
1: Error corrected at servo OFF
bit2:
0: Linear axis
1: Rotary axis
bit3:
0: Station assignment direction CW
1: Station assignment direction CCW
bit4:
0: Uniform assignment
1: Non-uniform assignment
bit5:
0: DO channel standard assignment
1: DO channel reverse assignment
bit6:
0: 2-wire detector communication
1: 4-wire detector communication
bit7:
0: Incremental detection
1: Absolute position detection
【#50103(PR)】 EmgCont Emergency stop control
The bits that are not explained here must be set to the default value.
Default value : bit0 = “1“, Other bits =”0”
bit0:
0: Enable external emergency stop
1: Disable external emergency stop
bit1:
0: Dynamic brake stop at emergency stop
1: Deceleration control stop at emergency stop
bit2:
0: Enable NC bus emergency stop input
1: Disable NC bus emergency stop input
bit3:
0: Enable NC bus emergency stop output
1: Disable NC bus emergency stop output