Specifications

II Parameters
Position Switches
II - 216
#7594 PSW10 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
(Note) This parameter is valid only when 1 set in "#7500 Pcheck".
#7601 PSW11 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
#7602 PSW11 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D0A
2nd part system device: X1D2A
---Setting range---
-99999.999 to 99999.999 (mm)
#7603 PSW11 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D0A
2nd part system device: X1D2A
---Setting range---
-99999.999 to 99999.999 (mm)
#7604 PSW11 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
(Note) This parameter is valid only when 1 set in "#7500 Pcheck".
#7611 PSW12 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
#7612 PSW12 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D0B
2nd part system device: X1D2B
---Setting range---
-99999.999 to 99999.999 (mm)
#7613 PSW12 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D0B
2nd part system device: X1D2B
---Setting range---
-99999.999 to 99999.999 (mm)
#7614 PSW12 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
(Note) This parameter is valid only when 1 set in "#7500 Pcheck".
#7621 PSW13 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address