Specifications

II Parameters
Position Switches
II - 213
#7522 PSW3 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D02
2nd part system device: X1D22
---Setting range---
-99999.999 to 99999.999 (mm)
#7523 PSW3 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D02
2nd part system device: X1D22
---Setting range---
-99999.999 to 99999.999 (mm)
#7524 PSW3 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
(Note) This parameter is valid only when 1 set in "#7500 Pcheck".
#7531 PSW4 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
#7532 PSW4 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D03
2nd part system device: X1D23
---Setting range---
-99999.999 to 99999.999 (mm)
#7533 PSW4 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D03
2nd part system device: X1D23
---Setting range---
-99999.999 to 99999.999 (mm)
#7534 PSW4 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
(Note) This parameter is valid only when 1 set in "#7500 Pcheck".
#7541 PSW5 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
#7542 PSW5 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D04
2nd part system device: X1D24
---Setting range---
-99999.999 to 99999.999 (mm)
#7543 PSW5 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D04
2nd part system device: X1D24
---Setting range---
-99999.999 to 99999.999 (mm)