Specifications
II Parameters
Position Switches
II - 212
10. Position Switches
(Note) This parameter description is common for M700V/M70V/E70 Series.
It is written on the assumption that all option functions are added.
Confirm with the specifications issued by the machine tool builder before starting use.
【#7500】 Pcheck High-speed switching of position switch
Specify whether to perform position switch area checking at high speeds.
0: Do not perform position switch area checking at high speed (do it the same as
before).
1: Perform position switch area checking at high speed.
【#7501】 PSW1 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
【#7502】 PSW1 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D00
2nd part system device: X1D20
---Setting range---
-99999.999 to 99999.999 (mm)
【#7503】 PSW1 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D00
2nd part system device: X1D20
---Setting range---
-99999.999 to 99999.999 (mm)
【#7504】 PSW1 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
(Note) This parameter is valid only when “1” set in "#7500 Pcheck".
【#7511】 PSW2 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address
【#7512】 PSW2 dog1 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D01
2nd part system device: X1D21
---Setting range---
-99999.999 to 99999.999 (mm)
【#7513】 PSW2 dog2 Imaginary dog position 2
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
1st part system device: X1D01
2nd part system device: X1D21
---Setting range---
-99999.999 to 99999.999 (mm)
【#7514】 PSW2 check Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
(Note) This parameter is valid only when “1” set in "#7500 Pcheck".
【#7521】 PSW3 axis Axis name
Specify the name of the axis for which a position switch is provided.
---Setting range---
X, Y, Z, U, V, W, A, B, or C axis address