Specifications

II Parameters
Macro List
II - 208
#7222 G[03] Type
Set the macro call out type.
0: Equivalent to M98 P △△△△ ;
1: Equivalent to G65 P △△△△ ;
2: Equivalent to G66 P △△△△ ;
3: Equivalent to G66.1 P △△△△ ;
Others: Equivalent to M98 P △△△△ ;
#7223 G[03] Program No.
Set the No. of the program or file name to be called out. The file name can contain up to 32
characters.
---Setting range---
Program name or file name (up to 32 characters)
#7231 G[04] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for
the G code call code, the G code call will have the priority, and these cannot be used as the
user macro I.
---Setting range---
1 to 999
#7232 G[04] Type
Set the macro call out type.
0: Equivalent to M98 P △△△△ ;
1: Equivalent to G65 P △△△△ ;
2: Equivalent to G66 P △△△△ ;
3: Equivalent to G66.1 P △△△△ ;
Others: Equivalent to M98 P △△△△ ;
#7233 G[04] Program No.
Set the No. of the program or file name to be called out. The file name can contain up to 32
characters.
---Setting range---
Program name or file name (up to 32 characters)
#7241 G[05] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for
the G code call code, the G code call will have the priority, and these cannot be used as the
user macro I.
---Setting range---
1 to 999
#7242 G[05] Type
Set the macro call out type.
0: Equivalent to M98 P △△△△ ;
1: Equivalent to G65 P △△△△ ;
2: Equivalent to G66 P △△△△ ;
3: Equivalent to G66.1 P △△△△ ;
Others: Equivalent to M98 P △△△△ ;
#7243 G[05] Program No.
Set the No. of the program or file name to be called out. The file name can contain up to 32
characters.
---Setting range---
Program name or file name (up to 32 characters)
#7251 G[06] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for
the G code call code, the G code call will have the priority, and these cannot be used as the
user macro I.
---Setting range---
1 to 999
#7252 G[06] Type
Set the macro call out type.
0: Equivalent to M98 P △△△△ ;
1: Equivalent to G65 P △△△△ ;
2: Equivalent to G66 P △△△△ ;
3: Equivalent to G66.1 P △△△△ ;
Others: Equivalent to M98 P △△△△ ;