Specifications
II Parameters
Macro List
II - 207
【#7102】 M2mac Type
Set the type for when calling out the macro with the 2nd miscellaneous command.
The macro will be called out with the "#1170 M2name" address command when "#1198
M2mac" is set to “1”.
0: Equivalent to M98 P △△△△ ;
1: Equivalent to G65 P △△△△ ;
2: Equivalent to G66 P △△△△ ;
3: Equivalent to G66.1 P △△△△ ;
Others: Equivalent to M98 P △△△△ ;
【#7103】 M2mac Program No.
Set the program No. for when calling out the macro with the 2nd miscellaneous command.
The macro will be called out with the "#1170 M2name" address command when "#1198
M2mac" is set to “1”.
Set the No. of the program or file name to be called out. The file name can contain up to 32
characters.
---Setting range---
Program name or file name (up to 32 characters)
【#7201】 G[01] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for
the G code call code, the G code call will have the priority, and these cannot be used as the
user macro I.
---Setting range---
1 to 999
【#7202】 G[01] Type
Set the macro call out type.
0: Equivalent to M98 P △△△△ ;
1: Equivalent to G65 P △△△△ ;
2: Equivalent to G66 P △△△△ ;
3: Equivalent to G66.1 P △△△△ ;
Others: Equivalent to M98 P △△△△ ;
【#7203】 G[01] Program No.
Set the No. of the program or file name to be called out. The file name can contain up to 32
characters.
---Setting range---
Program name or file name (up to 32 characters)
【#7211】 G[02] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for
the G code call code, the G code call will have the priority, and these cannot be used as the
user macro I.
---Setting range---
1 to 999
【#7212】 G[02] Type
Set the macro call out type.
0: Equivalent to M98 P △△△△ ;
1: Equivalent to G65 P △△△△ ;
2: Equivalent to G66 P △△△△ ;
3: Equivalent to G66.1 P △△△△ ;
Others: Equivalent to M98 P △△△△ ;
【#7213】 G[02] Program No.
Set the No. of the program or file name to be called out. The file name can contain up to 32
characters.
---Setting range---
Program name or file name (up to 32 characters)
【#7221】 G[03] Code
Set the G code to be used when calling the macro with a G command.
Do not set a G code used in the system.
G101 to G110 and G200 to G202 are user macro I codes. However, if a parameter is set for
the G code call code, the G code call will have the priority, and these cannot be used as the
user macro I.
---Setting range---
1 to 999