Specifications

II Parameters
Spindle Parameters
II - 183
#13124 SP124 ILMTsp Magnetic pole detection current limit value
Set the current limit value for the magnetic polar detection loop.
This is used in the initial magnetic polar detection when the IPM spindle motor is turned ON.
Set to "0" when using an IM spindle motor.
---Setting range---
0 to 999 (Short-time rated %)
#13125 SP125 DA1NO D/A output ch1 data No. / Initial DC excitation level
Input the desired data number to D/A output channel.
When using the 2-axis drive unit, set "-1" to the axis that the data will not be output.
When the DC excitation is running:
Use in the DC excitation function.
DC excitation: Set the initial excitation level when SP225/bit4=1.
When "0" is set, the state will be the same as when "20" is set.
---Setting range---
-32768 to 32767
#13126 SP126 DA2NO D/A output ch2 data No. / Final DC excitation level
Input the desired data number to D/A output channel.
When using the 2-axis drive unit, set "-1" to the axis that the data will not be output.
When the DC excitation is running:
Use in the DC excitation function.
DC excitation: Set the final excitation level when SP225/bit4=1.
When "0" is set, the state will be the same as when "50" is set.
---Setting range---
-32768 to 32767
#13127 SP127 DA1MPY D/A output ch1 output scale / Initial DC excitation time
Set the output scale in increments of 1/100.
When "0" is set, the scale is the same as when "100" is set.
When the DC excitation is running:
Use in the DC excitation function.
DC excitation: Set the initial excitation time when SP225/bit4=1.
When "0" is set, the state will be the same as when "10000" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
#13128 SP128 DA2MPY D/A output ch2 output scale
Set the output scale in increments of 1/100.
When "0" is set, the scale is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
#13129(PR) SP129
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and
specifications, so normally set the value given in the spindle parameter list.
#13130(PR) SP130
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and
specifications, so normally set the value given in the spindle parameter list.
#13131(PR) SP131
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and
specifications, so normally set the value given in the spindle parameter list.
#13132(PR) SP132
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and
specifications, so normally set the value given in the spindle parameter list.
#13133(PR) SP133
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and
specifications, so normally set the value given in the spindle parameter list.
#13134(PR) SP134
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and
specifications, so normally set the value given in the spindle parameter list.
#13135(PR) SP135
Set the unique constants for the spindle motor. (High-speed coil)
The setting value is determined by the motor's mechanical and electrical characteristics and
specifications, so normally set the value given in the spindle parameter list.