Specifications
II Parameters
Spindle Parameters
II - 179
【#13079】 SP079 IQG Q axis current gain
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is
selected.
The setting value is determined by the motor's electrical characteristics so that the value is
fixed to each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13080】 SP080 IDG D axis current gain
Set the current loop gain.
To use the coil switch function, set the current loop gain for when the high-speed coil is
selected.
The setting value is determined by the motor's electrical characteristics so that the value is
fixed to each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13081】 SP081 IQAL Q axis current lead compensation low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is
selected.
The setting value is determined by the motor's electrical characteristics so that the value is
fixed to each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 20480
【#13082】 SP082 IDAL D axis current lead compensation low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is
selected.
The setting value is determined by the motor's electrical characteristics so that the value is
fixed to each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 20480
【#13083】 SP083 IQGL Q axis current gain low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is
selected.
The setting value is determined by the motor's electrical characteristics so that the value is
fixed to each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13084】 SP084 IDGL D axis current gain low-speed coil
When using coil switch function, set the current loop gain for when the low-speed coil is
selected.
The setting value is determined by the motor's electrical characteristics so that the value is
fixed to each motor used.
Set the value given in the spindle parameter list. (For machine tool builder adjustment)
---Setting range---
1 to 8192
【#13085】 SP085
Not used. Set to "0".
【#13086】 SP086
Not used. Set to "0".
【#13087】 SP087 FHz4 Notch filter frequency 4
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bitB-9
---Setting range---
0 to 2250 (Hz)
【#13088】 SP088 FHz5 Notch filter frequency 5
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bitF-D
---Setting range---
0 to 2250 (Hz)