Specifications

II Parameters
Spindle Parameters
II - 171
MDS-DJ-SP Series: Regenerative resistor type
Set the regenerative resistor type.
bit F-8 : amp(bit F-C) / rtyp(bit B-8)
Setting prohibited : 10-12
MR-RB12 or GZG200W39OHMK : 13
MR-RB32 or GZG200W120OHMK 3 units connected in parallel : 14
MR-RB30 or GZG200W39OHMK 3 units connected in parallel : 15
MR-RB50 or GZG300W39OHMK 3 units connected in parallel : 16
Setting prohibited : 17-1F
Setting prohibited : 20-23
FCUA-RB22 : 24
FCUA-RB37 : 25
FCUA-RB55 : 26
FCUA-RB75/2 1 unit : 27
R-UNIT1 : 28
R-UNIT2 : 29
R-UNIT3 : 2A
R-UNIT4 : 2B
R-UNIT5 : 2C
FCUA-RB75/2 2 units connected in parallel: 2D
FCUA-RB55/2 2 units connected in parallel: 2E
Setting prohibited : 2F
bit 7-4 : emgx External emergency stop function
Set the external emergency stop function.
0: Disable 4: Enable
bit 3-0 :
Not used. Set to "0".
#13033 SP033 SFNC1 Spindle function 1
Select the spindle specification.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-C :
Not used. Set to "0".
bit B-A : ovs Overshoot compensation
Set this parameter when overshooting occurs during positioning.
bitB,A=
00: Compensation stop
01: Setting prohibited
10: Setting prohibited
11: Compensation type 3
Set the compensation amount in SP043(OVS1) and SP042(OVS2).
bit 9-8 : lmc Lost motion compensation type2
Set this parameter when the protrusion at quadrant change is too large.
bit9,8=
00: Compensation stop
01: Setting prohibited
10: Compensation type 2
11: Setting prohibited
bit 7 : lmc2a Lost motion compensation 2 timing
0: Normal 1: Change
bit 6 :
Not used. Set to "0".
bit 5-4 : vfct Jitter compensation pulse number
Suppress vibration by machine backlash when axis stops.
bit5,4=
00: Disable
01: 1 pulse
10: 2 pulse
11: 3 pulses
bit 3-0 :
Not used. Set to "0".
emgx
rtyp
amp
0000
vfct