Specifications
II Parameters
Servo Parameters
II - 148
【#2306】 SV106 PGM OMR-FF scale model gain
Set the scale model gain (position response) in OMR-FF control.
Set the same value as SV003(PGN1).
Increase the setting value to perform a high-speed machining such as a fine arc or to
improve the path error.
Lower the value when vibration occurs during acceleration/deceleration.
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 300 (rad/s)
【#2307】 SV107
Not used. Set to "0".
【#2308】 SV108
Not used. Set to "0".
【#2309】 SV109
Not used. Set to "0".
【#2310】 SV110
Not used. Set to "0".
【#2311】 SV111
Not used. Set to "0".
【#2312】 SV112 IFF OMR-FF current feed forward gain
Set the current feed forward rate in OMR-FF control.
The standard setting is "10000".
Setting value of 0 is equal to "10000(100%)" setting.
Set to "0" when not using OMR-FF control.
---Setting range---
0 to 32767 (0.01%)
【#2313】 SV113 SSF8 Servo function 8
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : ssc SLS (Safely Limited Speed) function
0: Stop 1: Start
bit E-9 :
Not used. Set to "0".
bit 8 : sto Dedicated wiring STO function
Set this parameter to use dedicated wiring STO function.
0: Dedicated wiring STO function unused 1: Dedicated wiring STO function used
bit 7-1 :
Not used. Set to "0".
bit 0 : omrffon OMR-FF control enabled
0: Disable 1: Enable
ssc
omrffon
sto