Specifications
II Parameters
Axis Specifications Parameters
II - 124
【#2199】 G1tMin Minimum time constant for cutting feed constant inclination acc./dec.
Acceleration/Deceleration is carried out so that the acceleration/deceleration time will not
become longer than this parameter's setting when the acceleration/deceleration type of
linear interpolation command is constant inclination.
Set a value smaller than "#2007 G1tL".
This parameter is enabled when "#1201 G1_acc" is constant inclination type.
This parameter is enabled only during fixed cycle if "#1253 set25 bit2" (Acceleration/
Deceleration mode change in hole drilling cycle) is enabled even if "#1200 G0_acc" is
constant inclination type.
This parameter is disabled if 0 or a value larger than "#2007 G1tL" is set.
---Setting range---
0 to 40000 (ms)
【#2561】 VBL2 VG1 Variable backlash comp II Changeover speed 1
Set the changeover speed at speed normalization.
Set a value smaller than that in "#2562 VBL2 VG0".
Normally, the "#2561 VBL2 VG1" value corresponds to the cutting feedrate, the "#2562
VBL2 VG0" value to the rapid traverse rate.
---Setting range---
1 to 1000000 (mm/min)
【#2562】 VBL2 VG0 Variable backlash comp II Changeover speed 2
Set the changeover speed at speed normalization.
Set a value greater than that in "#2561 VBL2 VG1".
Normally, the "#2561 VBL2 VG1" value corresponds to the cutting feedrate, the "#2562
VBL2 VG0" value to the rapid traverse rate.
---Setting range---
1 to 1000000 (mm/min)
【#2563】 VBL2 P1 Variable backlash comp II Stroke position 1
Set the most plus (+) side stroke position among the three.
Set the parameters VBL2 P1 to P3 to be "VBL2 P1 > VBL2 P2 > VBL2 P3".
Normally, divide the axis's stroke by four, and set a dividing position (except for the both
ends) to be a stroke position.
---Setting range---
-99999.999 to 99999.999 (mm)
【#2564】 VBL2 P2 Variable backlash comp II Stroke position 2
Set the middle stroke position among the three.
Set the parameters VBL2 P1 to P3 to be "VBL2 P1 > VBL2 P2 > VBL2 P3".
Normally, divide the axis's stroke by four, and set a dividing position (except for the both
ends) to be a stroke position.
---Setting range---
-99999.999 to 99999.999 (mm)
【#2565】 VBL2 P3 Variable backlash comp II Stroke position 3
Set the most minus (-) side stroke position among the three.
Set the parameters VBL2 P1 to P3 to be "VBL2 P1 > VBL2 P2 > VBL2 P3".
Normally, divide the axis's stroke by four, and set a dividing position (except for the both
ends) to be a stroke position.
---Setting range---
-99999.999 to 99999.999 (mm)
【#2566】 VBL2 BL11 Variable backlash comp II Comp data at changeover spd 1 and stroke
pos 1
Set the compensation data (backlash amount) at changeover speed 1 and stroke position 1.
Calculate the current compensation data according to the current speed and position.
---Setting range---
-99999999 to 99999999 (Machine error compensation unit)
【#2567】 VBL2 BL12 Variable backlash comp II Comp data at changeover spd 1 and stroke
pos 2
Set the compensation data (backlash amount) at changeover speed 1 and stroke position 2.
Calculate the current compensation data according to the current speed and position.
---Setting range---
-99999999 to 99999999 (Machine error compensation unit)
【#2568】 VBL2 BL13 Variable backlash comp II Comp data at changeover spd 1 and stroke
pos 3
Set the compensation data (backlash amount) at changeover speed 1 and stroke position 3.
Calculate the current compensation data according to the current speed and position.
---Setting range---
-99999999 to 99999999 (Machine error compensation unit)