Specifications

I Alarms
Stop Codes (T)
I - 13
2. Stop Codes (T)
T01 Axis in motion 0101
Details
Automatic start is not possible as one of the axes is moving.
Remedy
- Try automatic start again after all axes have stopped.
T01 NC not ready 0102
Details
Automatic start is not possible as the NC is not ready.
Remedy
- Another alarm has occurred. Check the details and remedy.
T01 Reset signal ON 0103
Details
Automatic start is not possible as the "reset" signal has been input.
Remedy
- Turn OFF the "reset" signal.
- Check for any failure of the reset switch which has caused the switch's continuous ON.
- Correct the sequence program.
T01 Auto operation pause signal ON 0104
Details
The feed hold switch on the machine operation panel is ON (valid).
Remedy
- Correct the feed hold switch setting.
- The feed hold switch is B contact switch.
- Fix any broken wires in the feed hold signal line.
- Correct the sequence program.
T01 H/W stroke end axis exists 0105
Details
Automatic start is not possible as one of the axes is at the stroke end.
Remedy
- Manually move any axis whose end is at the stroke end.
- Check for any broken wires in the stroke end signal line.
- Check for any failure in the stroke end limit switch.
T01 S/W stroke end axis exists 0106
Details
Automatic start is not possible as one of the axes is at the stored stroke limit.
Remedy
- Move the axis manually.
- If the axis's end is not at the stroke end, check the parameters.
T01 No operation mode 0107
Details
The operation mode has not been selected.
Remedy
- Select automatic operation mode.
- Check for any broken wires in the signal line for automatic operation mode (memory, tape,
MDl).
T01 Operation mode duplicated 0108
Details
Two or more automatic operation modes have been selected.
Remedy
- Check for any short circuit in the mode (memory, tape, MDl) selection signal line.
- Check for any failure in the switch.
- Correct the sequence program.
T01 Operation mode changed 0109
Details
The automatic operation mode has changed to another automatic operation mode.
Remedy
- Return to the original automatic operation mode, and execute automatic start.
T01 Tape search execution 0110
Details
Automatic start is not possible as tape search is being executed.
Remedy
- Wait for the tape search to be completed and then execute the automatic start.
T01 Cycle start prohibit 0111
Details
Automatic start is disabled because restart search is in execution.
Remedy
- Execute automatic start after the restart search is completed.
T01 CNC overheat 0113
Details
Automatic start is not possible because a thermal alarm (Z53 CNC overheat) has occurred.
Remedy
- Temperature of the control unit has exceeded the specified temperature.
- Take appropriate measures to cool the unit.
T01 Cycle st. prohibit(Host comm.) 0115
Details
Automatic start cannot is not possible because the NC is communicating with the host com-
puter.
Remedy
- Wait for the communication with host computer to be ended and then execute the automatic
start.