Specifications
II Parameters
Axis Specifications Parameters
II - 112
【#2051】 check Check
Set the tolerable range of travel distance (deviation distance) while the power is turned
OFF.
If the difference of the positions when the power is turned OFF and when turned ON again
is larger than this value, an alarm will be output.
Set "0" to omit the check.
---Setting range---
0 to 99999.999 (mm)
【#2054】 clpush Current limit (%)
Set the current limit value during the stopper operation in the dogless-type absolute position
detection.
The setting value is the ratio of the current limit value to the rated current value.
---Setting range---
0 to 100 (%)
【#2055】 pushf Push speed
Set the feedrate for the automatic initial setting during stopper method.
---Setting range---
1 to 999 (mm/min)
【#2056】 aproch Approach
Set the approach distance of the stopper when deciding the absolute position basic point
with the stopper method.
After using stopper once, the tool returns with this distance, and then use stopper again.
---Setting range---
0 to 999.999 (mm)
【#2057】 nrefp Near zero point +
Set the positive direction width where the near reference position signal is output.
When set to "0", the width will be equivalent to the grid width setting.
(Note) When "#1240 set12/bit2" is ON, a magnification (C: 10-fold, D: 100-fold, E:1000-fold)
corresponding to the input setting increment ("#1003 iunit") will be applied to the
setting value.
---Setting range---
0 to 999.999 (mm)
(Input setting increment applied)
【#2058】 nrefn Near zero point -
Set the negative direction width where the near reference position signal is output.
When set to "0", the width will be equivalent to the grid width setting.
(Note) When "#1240 set12/bit2" is ON, a magnification (C: 10-fold, D: 100-fold, E:1000-fold)
corresponding to the input setting increment ("#1003 iunit") will be applied to the
setting value.
---Setting range---
0 to 999.999 (mm)
(Input setting increment applied)
【#2059】 zerbas Select zero point parameter and basic point
Select which is to be the zero point coordinate position during absolute position initial
setting.
0: Position where the axis was stopped.
1: Grid point just before stopper.
【#2061】 OT_1B- Soft limit IB-
Set the coordinate of the lower limit of the area where the stored stroke limit IB is inhibited.
Set a value from zero point in the basic machine coordinate system.
If the same value (non-zero) with the same sign as that of "#2062 OT_IB+" is set, the stored
stroke limit IB function will be disabled.
---Setting range---
-99999.999 to 99999.999 (mm)
【#2062】 OT_1B+ Soft limit IB+
Set the coordinate of the upper limit of the area where the stored stroke limit IB is inhibited.
Set a value from zero point in the basic machine coordinate system.
---Setting range---
-99999.999 to 99999.999 (mm)
【#2063】 OT_1B type Soft limit IB type
Select the type that applies the settings of "#2062 OT_IB+" and "#2061 OT_IB-" in stored
stroke limit I.
0: Soft limit IB
1: The settings are invalid
2: Soft limit IC
3: Soft limit is checked for the inclined axis control axis with the program coordinate
system.
(Note) This is valid only for inclined axis' base axis and inclined axis.