Specifications

II Parameters
Axis Specifications Parameters
II - 111
#2038 #2_rfp Reference position #2
Set the position of the second reference position from the zero point of the basic machine
coordinate.
---Setting range---
-99999.999 to 99999.999 (mm)
#2039 #3_rfp Reference position #3
Set the position of the third reference position from the zero point of the basic machine
coordinate.
---Setting range---
-99999.999 to 99999.999 (mm)
#2040 #4_rfp Reference position #4
Set the position of the fourth reference position from the zero point of the basic machine
coordinate.
---Setting range---
-99999.999 to 99999.999 (mm)
#2049(PR) type Absolute position detection method
Select the absolute position zero point alignment method.
0: Not absolute position detection
1: Stopper method (push against mechanical stopper)
2: Marked point alignment method I (The grid point is the reference position.)
3: Dog-type (align with dog and near point detection switch)
4: Marked point alignment method II (The position with which the mark was aligned is
the reference position.)
9: Simple absolute position (Not absolute position detection, but the position when the
power is turned off is registered.)
#2050 absdir Basic point of Z direction
Select the direction of the grid point immediately before the machine basic position (basic
point of detector) in the marked point alignment.
0: Positive direction
1: Negative direction
Reference position #3
(#2039 #3_rfp)
Basic machine coordinate
Reference position #4
(#2040 #4_rfp)
Reference position #2
(#2038 #2_rfp)
Reference position #1
(#2037 G53ofs)
Reference position #3
(#2039 #3_rfp)
Basic machine coordinate
Reference position #4
(#2040 #4_rfp)
Reference position #2
(#2038 #2_rfp)
Reference position #1
(#2037 G53ofs)
Reference position #3
(#2039 #3_rfp)
Basic machine coordinate
Reference position #4
(#2040 #4_rfp)
Reference position #2
(#2038 #2_rfp)
Reference position #1
(#2037 G53ofs)