Specifications
II Parameters
Base Specifications Parameters
II - 103
【#12010(PR)】 Tbin T binary
Data type 0 BCD
Data type 1 Unsigned binary
Data type -1 Singed binary
<For unsigned binary>
The absolute value "1" is output for "-1".
<For singed binary>
"-1" is output as "0xFFFFFFFF".
---Setting range---
Data type
(-1,0,1)
【#12011(PR)】 Bfig Number of B
Set the number of T that can be specified within the same block.
---Setting range---
1 to 4
【#12012(PR)】 Bbin B binary
Data type 0 BCD
Data type 1 Unsigned binary
Data type-1 Singed binary
<For unsigned binary>
The absolute value "1" is output for "-1".
<For singed binary>
"-1" is output as "0xFFFFFFFF".
---Setting range---
Data type
(-1,0,1)
【#12013】 G33.n rot G33.n rotary axis name
Select the axis to use as C axis with its axis name.
---Setting range---
A to Z
【#12014】 G33.n ovr G33.n override
Not used.