Specifications
II Parameters
Base Specifications Parameters
II - 102
【#12001】 ManualB RectanA xH Manual feed rate B constant surface control intersecting
part system axis name (horizontal)
Set the part system axis name ("#1013 axname") for the two axes that intersect with the
rotary axis direction. When one of the two axes is blank, a constant speed will be applied
without using constant surface speed control.
---Setting range---
Axis addresses such as X, Y, Z, U, V, W, A, B, and C
【#12002】 ManualB RectanA xV Manual feed rate B constant surface control intersecting
part system axis name (vertical)
Set the part system axis name ("#1013 axname") for the two axes that intersect with the
rotary axis direction. When one of the two axes is blank, a constant speed will be applied
without using constant surface speed control.
---Setting range---
Axis addresses such as X, Y, Z, U, V, W, A, B, and C
【#12003】 ManualB RotCent erH Manual feed rate B constant surface control rotation center
machine position (horizontal)
Set the machine coordinate position (horizontal axis) at the center of the rotary axis.
---Setting range---
-99999.999 to 99999.999 (mm)
【#12004】 ManualB RotCent erV Manual feed rate B constant surface control rotation center
machine position (vertical)
Set the machine coordinate position (vertical axis) at the center of the rotary axis.
---Setting range---
-99999.999 to 99999.999 (mm)
【#12005(PR)】 Mfig Number of M
Set the number of M that can be specified within the same block.
---Setting range---
1 to 4
【#12006(PR)】 Mbin M binary
Data type 0 BCD
Data type 1 Unsigned binary
Data type -1 Singed binary
<For unsigned binary>
The absolute value "1" is output for "-1".
<For singed binary>
"-1" is output as "0xFFFFFFFF".
---Setting range---
Data type
(-1,0,1)
【#12007(PR)】 Sfig Number of S
Set the number of spindles.
(Note 1) The setting range differs according to the model.
(Note 2) Sfig is set in the range of 1 to 6. However, the number of outputs by Sfig cannot be
controlled. Thus, only one S command is output regardless of the Sfig setting value.
---Setting range---
1 to 6
【#12008(PR)】 Sbin S binary
Data type 0 BCD
Data type 1 Unsigned binary
Data type -1 Singed binary
<For unsigned binary>
The absolute value "1" is output for "-1".
<For singed binary>
"-1" is output as "0xFFFFFFFF".
(Note 1) Sbin can be set with "-1", "0" and "1", but the S command cannot be BCD output.
If BCD (0) is selected for Sbin, it will be handled as a singed binary (-1).
---Setting range---
Data type
(-1,0,1)
【#12009(PR)】 Tfig Number of T
Set the number of T that can be specified within the same block.
---Setting range---
1 to 4