Specifications

II Parameters
Base Specifications Parameters
II - 101
#11035 Sys. change limit Part system switching restriction
This restricts switching the part systems displayed on screen.
0: Not restrict
1: Disable the part system switching by pressing [$<->$] key on touch panel.
2: Disable the part system switching by display switch signals(Y730 to Y733).
#11036 meas dir judge Non-sensitive band for manual measurement direction judgment
(for M system only)
Set the non-sensitive band to be used for judging the manual measurement direction. If the
feedback position fluctuates widely at the axis stop, set the fluctuation width or larger value
in this set the parameter.
When set to "0", the band will be 1 (µm).
---Setting range---
0 to 1000 (µm)
0: 1 (µm)
#11037 R-Navi Index Type R-Navi machining surface indexing type
Select the machining surface indexing type in the R-Navi function.
0: Indexing type 1 (Only rotary axes move to perform indexing)
1: Indexing type 2 (Indexing is performed with the tool center point fixed to the position
seen from the workpiece)
#11038 T disp typ T display (tool command value) type (For L system only)
Select the T display (tool command value) type on the monitor screen between displaying
tool No. only or displaying tool No. and compensation No. (L system only)
0: Display tool No. only
1: Display the tool command value (the combined value consisting of the tool No. and
compensation No.) last commanded by the program. Even in a manual value
command, the program's tool command value is displayed.
#11039 Cusr pos srch type Cursor position search type
Set the availability of the cursor position search during single block stop when #11031
Cursor pos search=1 to 3.
0: Disable cursor position search during single block stop.
1: Enable cursor position search during single block stop.
Sub-program is displayed when selecting menus [Monitr]-[Edit] while single block stop is
carried out during sub-program with this parameter set to 1.
#11050(PR) T-ofs digit type Tool compensation digit type
Change the setting range for a tool compensation amount, tool management, and tool
shape setting of tool compensation types I and II of M system.
This change is also reflected in the tool compensation screen and tool measurement
screen.
0: Set with a 3-digit integer
1: Set with a 4-digit integer
#11051 Direct Socket OFF Direct Socket communication I/F OFF
Select ON/OFF of the Direct Socket communication I/F.
0: ON (Default)
1: OFF
(Note) When the Direct Socket communication I/F is ON, applications that uses "#1926
Global IP address" such as MS Configurator and GX Developer cannot be used.
#11052 LOG Sort Order Log data sorting order
Select in which order to sort the operation log files (all logs) to be output.
0: Sort the data in chronologically ascending order separately for each log type.
1: Sort the data in chronologically ascending order for all the log types.
If the times and dates logged are identical, the files are output in the order of key,
alarm, PLC signal and AC power error logs.
#11101-11130(PR) Monitr menu(MTB)1-30 Monitor main menu (MTB) 1 to 30
Designate the destination menu Nos. to move monitor screen's main menus.
-1 : Menu not displayed
0 : No change
1 to 30: Destination menu Nos.
#11151-11180(PR) Setup menu(MTB) 1-30  Setup main menu (MTB) 1 to 30
Designate the destination menu Nos. to move setup screen's main menus.
-1 : Menu not displayed
0 : No change
1 to 30: Destination menu Nos.
#11201-11230(PR) Edit menu(MTB) 1-30  Edit main menu (MTB) 1 to 30
Designate the destination menu Nos. to move edit screen's main menus.
-1 : Menu not displayed
0 : No change
1 to 30: Destination menu Nos.