Specifications

II Parameters
Base Specifications Parameters
II - 99
#11009(PR) M2 label O M2 label O
Select the program number label when using the M2 format.
0: Label L
1: Label O
#11010(PR) Software keyboard Software keyboard
Select with touch panel whether to use software keyboard.
0: Do not use
1: Use
2: Use (Note1)
(Note1) Software keyboard automatically appears on a specific screen. (For M700VS/
M70V/M70 Series only).
#11011 Handy TERM. PW. Handy terminal password
Set the password used for the handy terminal customized downloading.
Blank (when "0" is set) and "0000" are regarded as no password.
Not the password of a new customizing file but the password of the customizing file
downloaded to the last handy terminal is set.
Set blank or "0000" when initially downloading.
---Setting range---
0000 to 9999
#11012(PR) 16 axes for 1ch Connecting 16 axes for 1ch
Select the maximum number of axes (sum of the NC axis, spindle, and PLC axis) connected
to the drive unit interface (channel 1) when not using the extension unit (FCU7-
EX891+HN552)
0: Up to 8 axes can be connected to channel 1.
1: Up to 16 axes can be connected to channel 1. This parameter is disabled when the
extension unit is connected. It is possible to connect only up to eight axes or less per
channel.
#11013 3D_MChk Invalidate 3D machine interference check
Select whether to enable the 3D machine interference check function.
0: Enable
1: Disable
#11014 Chk_len1 1st-step interference check distance
Set the 1st-step check distance when in 3D machine interference check mode.
The standard value is "30.000".
---Setting range---
0.000 to 99999.999(mm)
#11015 Chk_len2 2nd-step interference check distance
Set the 2nd-step check distance when in 3D machine interference check mode.
The standard value is "5.000".
---Setting range---
0.000 to 99999.999(mm)
#11016 Expand_Rate Shape expansion rate
Set the model shape expansion rate to be used for 3D machine interference check. This
parameter is used for expanding a model shape to be used for 3D machine interference
check. The interference check is performed using a shape expanded by the amount of
[Check length (mm) x Shape expansion rate (%)].
---Setting range---
0 to 300(%)
#11017 T-ofs set at run
Select whether to enable the tool compensation amount setting and life value setting during
automatic operation and operation pause.
0: Disable
1: Enable
#11018 M password hold
Select whether to enable the "Machine user" password holding.When this is set to "1", the
"Machine user" password will be held.
0: Disable
1: Enable
#11019 2-system display 2-part system simultaneous display
Select whether to validate 2-part system simultaneous display on operation screen.
0: Display one part system on operation screen
1: Display two part systems simultaneously on operation screen
2: Display two part systems simultaneously (Display type 2) on operation screen
(Note 1) Unless you set "1" in two or more of "#1001 SYS_ON [1] to [4]", two-part system
simultaneous display will fail regardless of this parameter.
#11021 PLC mesg disp type Format of PLC alarm and operator message
Select the format of PLC alarms and operator messages to be displayed on the bottom right
of the screen.
0: Display up to the first 40 characters.
1: If text is longer than 40 characters, divide it into two and display separately.
(Classification No. is displayed together)