Specifications
II Parameters
Base Specifications Parameters
II - 98
【#1928(PR)】 Global Gateway Gateway
Set the IP address for the gateway.
【#1929】 Port number Port No.
Set the port No. for the service function.
---Setting range---
1 to 9999
(Set 2000 when not connected to the Ethernet.)
【#1930(PR)】 Host address Host address
Set the host's IP address.
【#1931(PR)】 Host number Host No.
Set the host's port No.
---Setting range---
1 to 9999
【#1934(PR)】 Local IP address
Set the HMI side CPU's IP address.
(Note) This parameter is valid only for M700/M700VW Series.
【#1935(PR)】 Local Subnet mask
Set the HMI side CPU's subnet mask.
(Note) This parameter is valid only for M700/M700VW Series.
【#11001(PR)】 APC type APC screen display type selection
Set the type of screen displayed with the pallet program registration screen.
0: Standard pallet registration screen
1: Pallet 4-page registration screen
【#11002(PR)】 Valid pallet num Number of pallets setting
Set the number of pallets validated on the pallet program registration screen.
---Setting range---
2 to 12 (Interpreted as 2 when 0 is set.)
【#11003(PR)】 APLC valid APLC valid
Temporarily disable APLC.
Normally set "1".
0: Disable
1: Enable
【#11004(PR)】 PLCauto-run enable PLC automatic startup valid
Select starting condition of the built-in PLC.
0: Start PLC after NC screen startup
1: Start PLC at NC startup
(Note) When standard NC screen is not used, set "1".
【#11005(PR)】 PC IP address IP address setting
Set the IP address for the display unit or PC in which machining programs are stored.
Set the IP address for the display unit on which the automatic power OFF will be executed.
When the 3D machine interference check function is enabled, set the IP address of the
display unit that is used for the 3D machine interference check (for M700VW only).
(Note 1) When “0.0.0.0” is input, “192.168.100.2” is automatically set.
(Note 2) This parameter is valid only for M700VW/M700 Series.
PC Subnet
Set the subnet mask for the display unit or PC in which machining programs are stored.
PC Gateway
Set the gateway for the display unit or PC in which machining programs are stored.
【#11006】 PC Port number Port No. setting
Set the port No. for the display unit or PC in which machining programs are stored.
(Note 1) When "0" is input, "55555" is automatically set.
(Note 2) When changing the parameter, set the same value in "PD_Control_Port" in the PC
side environment setting file.
---Setting range---
0 to 65535
【#11007】 PC Timeout Communication timeout time setting
Set the NC side communication timeout time.
(Note 1) When "0" is input, "120" is automatically set.
(Note 2) When the value greater than "300" is set, a setting error occurs.
(Note 3) When changing the parameter, set the same value in "PD_Time_out" in the PC
side environment setting file.
---Setting range---
0 to 300 (s)