Specifications

I Alarms
Operation Errors (M)
I - 11
M01 Cont ax superimpos II prm illg 1044
内容
- There is a mistake in the setting of the superimposition control base axis parameter (#2089
bsax_pl).
- Superimposition control is not available under the current parameter settings.
処置
- Correct the parameter.
M01 Sp synchro phase calc illegal 1106
Details
Spindle synchronization phase alignment command was issued while the "phase shift calcu-
lation request" signal was ON.
Remedy
- Correct the program.
- Correct the sequence program.
M01 GB SP sync:Cancel sgnl illegal 1137
Details
The guide bushing spindle synchronization temporary cancel signal was turned ON/OFF when
the master spindle and G/B spindle were in one of the following modes.
- During rotation (when not stopped)
- During tap cycle synchronization mode
- During spindle synchronization mode
- During tool-spindle synchronization I (polygon machining) mode
- During tool-spindle synchronization II (hobbing) mode
- During spindle C axis control C axis mode
- During orientation/indexing
Remedy
- Check the ladder program.
M01 GB SP sync runs independently 1138
Details
- The reference spindle was commanded as a spindle related to tool spindle synchronization
IC (polygon).
- The guide bushing spindle was commanded as a synchronous tapping spindle.
- The guide bushing spindle was commanded as a spindle related to spindle synchronization/
tool spindle synchronization I (polygon)/tool spindle synchronization II (hobbing).
Remedy
- Check the program.
M80 POSITION ERROR
Details
An axis position is illegal.
An alarm is displayed (AL4 is output) and a block stop is applied on the machining program.
When the block stop is not allowed in the thread cutting cycle and the like, the stop is applied
at the next position where allowed.
Remedy
Carry out reset. Then confirm that the system starts the operation. If the alarm is displayed
again, turn ON the emergency stop switch and turn the NC power OFF and ON.
M90 Parameter set mode
Details
The lock for setup parameters has been released. Setting the setup parameters is enabled
while automatic start is disabled.
Remedy
Refer to the manual issued by the machine tool builder.
M91 INVALID MEASUR. 0002
Details
Data is over the range
The measurement result exceeds the tool data setting range.
Remedy
Correct the settings of "#2015 tlml- (Negative direction sensor of tool setter)" and "#2016 tlml+
(Positive direction sensor of tool setter or TLM standard length)".
M91 INVALID MEASUR. 0003
Details
No corresponding No.
No measurement tool No. has been set.
The registered No. is out of the specifications.
Remedy
Correct the measurement tool No.
M91 INVALID MEASUR. 0045
Details
Measurement axis illegal
Sensor has been turned ON while two or more axes are moving.
Remedy
Move a single axis when the sensor is contacted.
M91 INVALID MEASUR. 0046
Details
Measurement axis has not returned to reference position
Reference position return has not been executed on a measurement axis in an incremental
system.
Remedy
Carry out the reference position return on the measurement axis before measuring the tool.