Specifications
II Parameters
Base Specifications Parameters
II - 91
【#1401】 M_mode M command operation selection
Select the M command operation.
(Note) Register M codes in the special operation registration M codes (#1411 to #1418).
0: Not wait for the completion of registered M codes,
but wait for the completion of the other M codes
1: Wait for the completion of registered M codes,
but not wait for the completion of the other M code
【#1402】 S_mode S command completion method selection
Select the S command completion method.
0: Wait for the complete signal from PLC
1: Not wait for the complete signal from PLC
【#1403】 T_mode T command completion method selection
Select the T command completion method.
0: Wait for the complete signal from PLC
1: Not wait for the complete signal from PLC
【#1404】 M2_mode 2nd miscellaneous command completion method selection
Select the 2nd miscellaneous command completion method.
0: Wait for the complete signal from PLC
1: Not wait for the complete signal from PLC
【#1411】 M_wait[M031-000] Special operation registration M code
Register an M code that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF (hexadecimal)
【#1412】 M_wait[M063-032] Special operation registration M code
Register an M code (32 to 63) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF (hexadecimal)
【#1413】 M_wait[M095-064] Special operation registration M code
Register an M code (64 to 95) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF (hexadecimal)
【#1414】 M_wait[M127-096] Special operation registration M code
Register an M code (96 to 127) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF (hexadecimal)
【#1415】 M_wait[M159-128] Special operation registration M code
Register an M code (128 to 159) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF (hexadecimal)
【#1416】 M_wait[M191-160] Special operation registration M code
Register an M code (160 to 191) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF (hexadecimal)
【#1417】 M_wait[M223-192] Special operation registration M code
Register an M code (192 to 223) that needs special operation.
Each bit of the setting value corresponds to the M code number.
(Example) To register M05, set 00000020 in #1411.
(Note) Note that the registered M code operation varies according to M_mode (#1401).
---Setting range---
0 to FFFFFFFF (hexadecimal)