Specifications
II Parameters
Base Specifications Parameters
II - 87
【#1295(PR)】 ext31
Not used. Set to "0".
【#1296(PR)】 ext32
Not used. Set to "0".
【#1297(PR)】 ext33
Not used. Set to "0".
【#1298(PR)】 ext34
Not used. Set to "0".
【#1299(PR)】 ext35
Not used. Set to "0".
【#1300(PR)】 ext36
bit0: Multiple spindle control II
Select multiple spindle control I or II.
0: Multiple spindle control I (L system only)
1: Multiple spindle control II (select from ladder)
bit7: Spindle synchronization command method
Select the spindle synchronization command method.
0: Spindle synchronization with PLC I/F
1: Spindle synchronization with machining program
【#1301】 nrfchk Near reference position check method
Select the method to judge the "near reference position".
0: Conventional method
1: Command machine position is used.
2: Feedback position is used.
【#1302】 AutoRP Automatic return by program restart
Select the method to move to the restart position when restarting the program.
0: Move the system manually to the restart position and then restart the program.
1: The system automatically moves to the restart position at the first activation after the
program restarts.
【#1303(PR)】 V1comN No. of #100 address part system common variables
Set the number of common variables, common for part systems, starting from address
#100.
This is valid only when "#1052 MemVal" is set to "1".
---Setting range---
0 to 100
【#1304(PR)】 V0comN No. of #500 address part system common variables
Set the number of common variables, common for part systems, starting from address
#500.
This is valid only when "#1052 MemVal" is set to "1".
---Setting range---
0 to 500
【#1306】 InpsTyp Deceleration check specification type
Select the parameter specification type for the G0 or G1 deceleration check.
0: Deceleration check specification type 1
G0 is specified with "#1193 inpos", and G1+G9 with "#1223 aux07/bit1".
1: Deceleration check specification type 2
G0 or G1+G9 is specified with "#1193 inpos".
【#1309(PR)】 GType Switch command format
Select which is used to command the reverse tap.
0: G84.1/G88.1
1: D command with the value changed to negative
【#1310】 WtMmin Minimum value for synchronization M code
Set the minimum value for the M code. When "0" is set, the synchronization M code will be
invalid.
---Setting range---
0, 100 to 99999999
【#1311】 WtMmax Maximum value for synchronization M code
Set the maximum value for the M code. When "0" is set, the synchronization M code will be
invalid.
---Setting range---
0, 100 to 99999999