Specifications

II Parameters
Base Specifications Parameters
II - 81
#1274(PR) ext10
bit4: Optional block skip operation changeover
Select the optional block skip operation.
0: Enable or disable optional block skipping in the middle of a block according to the
setting of "#1226 aux10/bit1".
1: Enable optional block skipping at the top and in the middle of a block. Note that a
slash "/" on the right-hand side of equation or that in an equation between [ ] is
handled as division operator.
bit7: Word range check
Select whether to check that the operation expression of the word data in the program is
enclosed in brackets ( [ ] ) when the machine program is executed.
This check is also applied to the 08000 to 09999 and the machine tool builder macro
program.
0: Not check
1: Check
#1275(PR) ext11
Not used. Set to "0".
#1276(PR) ext12
Not used. Set to "0".
#1277(PR) ext13
bit0: Tool life management II count type 2
Select how and when the mount or use count will be incremented in tool life management II.
The condition to output "tool group life over (TGLO)" signal will be changed accordingly.
0: Type 1 (Default)
Counts up when the spindle tool is used for cutting.
TGLO signal will be output when the last tool in selected group is judged as expired.
1: Type 2
Counts up by one for a tool used or mounted in a program at the time of resetting.
TGLO signal will be output when any of tool groups has reached its lifetime limit.
bit1: Tool life management II life prediction
Select whether to enable tool life prediction function in tool life management II.
0: Disable
1: Enable
bit2: Tool life management II life end signal timing
Select the timing at which tool life prediction signal is output in tool life management II.
0: Output only when the ["life value" - "used value"] matches the remaining life.
("life value" - "used value" = "remaining life")
1: Output when the ["life value" - "used value"] is less than the remaining life.
("life value" - "used value" "remaining life")
bit3: Tool life management II life end signal tool
Select the tool for which the tool life prediction signal is output in tool life management II.
0: Output the signal tool by tool.
1: Output the signal at the last tool in the group.
bit4: Tool life management II count changeover (For M system only)
Select the tool life count method and its timing.
0: Conforms to "ext13/bit0" setting.
1: When "ext13/bit0" is set to "0":
Counts up by one for a tool used or mounted in a program at the time of resetting.
When "ext13/bit0" is set to "1":
Follow the setting of "Method (Mthd)" on Tool life screen.
The output condition of "tool group life over" signal conforms to "ext13/bit0".
#1278(PR) ext14
bit0: Program restart method selection
Select the program restart type.
0: Restart type A
1: Restart type B
bit1: Change miscellaneous command completion method
Select the complete signal and completion condition.
0: Normal method
Complete at the falling edge of M function finish 1 signal (FIN1) or rising edge of M
function finish 2 (FIN2).
1: High-speed method
Complete when High-speed M finish signal (MFIN1 to 4, SFIN1 to 6, TFIN1 to 4 or
BFIN1 to 4) reaches the same logical level as the strobe signal.
bit2: Change areas for stored stroke limit I
Enable/Disable change of the areas for stored stroke limit I.
0: Disable
1: Enable