Specifications
II Parameters
Base Specifications Parameters
II - 75
【#1239(PR)】 set11
bit0: Coil switching method
Select the coil switching method.
0: Via PLC (Y189F).
1: NC internal processing. (Y189F is invalid.)
bit1: Handle I/F selection
Select the handle connection destination.
0: Use the handle connected to the encoder communication connector.
1: Use the remote I/O unit as a priority.
When HN341/HN342/HN351/HN391/HN392 is mounted, the handle connected to the
operation panel I/O unit will be used regardless of this parameter setting.
bit3: Polygon machining mode at reset
Select whether to cancel the polygon machining mode when reset is applied.
0: Not cancel.
1: Cancel.
bit4: Invalidate G51.1 phase command
Select whether to enable the phase control with the spindle-spindle polygon function.
0: Always enable. (When R is not commanded, it will be handled as R0.)
1: Enable only at the R command.
bit5: Door interlock spindle speed clamp valid
Select whether to enable the spindle clamp speed changeover by the PLC signal.
0: Disable
1: Enable
【#1240(PR)】 set12
bit0: Handle input pulse
Select the handle input pulse.
0: MITSUBISHI CNC standard handle pulse (25 pulse/rev)
1: Handle 400 pulse (100 pulse/rev)
bit4: Optical communication automatic channel detection invalid
Select whether to enable the optical communication automatic channel detection.
0: Enable
1: Disable
【#1241(PR)】 set13
bit0 : No G-CODE COMB. Error
Select the operation for when an illegal combination of modal and unmodal G codes are
commanded in a same block.
0:The program error (P45) will occur.
1:A program error can be avoided but the modal G code will be ignored.
bit1: Interference check at starting up radius compensation (for M system only)
0: In a start-up block, an interference check is not carried out.
1: An error occurs even at a start-up block if an interference occurs.
The error occurs even when the interference avoidance is set to ON (#8102="1").
However, an interference check is not carried out when it is set to OFF (#8103="1").
【#1242】 set14
Not used. Set to "0".
【#1243】 set15
Not used. Set to "0".
【#1244】 set16
Not used. Set to "0".
【#1245】 set17
bit7: Synchronous tap spindle rotation direction type
Select whether the spindle's rotation direction is determined by the synchronous tapping
axis' travel direction.
0: The spindle's rotation direction is determined by the synchronous tapping axis' travel
direction.
When the travel direction is negative, the spindle rotates forward.
When the travel direction is positive, the spindle rotates in reverse.
1: The spindle always rotates forward regardless of the synchronous tapping axis' travel
direction.
(Note)When a reverse tap is commanded, the spindle rotates in an opposite direction to that
mentioned above.