Specifications
II Parameters
Base Specifications Parameters
II - 71
【#1227】 aux11
bit0: Select PLC signal or spindle feedrate attained
Set up this option when disabling the cutting start interlock by spindle feedrate attained.
0: Cutting start interlock by PLC signal
1: Cutting start interlock by spindle feedrate attained
bit1: Select H or D code
Set up this option to validate the data that is set up on the tool life management screen
when issuing the H99 or D99 command.
0: The H and D codes validate the data that is set up on the management setup screen.
1: Validates the data that is set up on the management setup screen when issuing the
H99 or D99 command.
bit2: Measures against tool setter chattering
Select a condition where a relieving operation completes after measurement with tools.
0: Sensor signals have stopped for 500 ms or longer.
1: 100 μm or longer has passed after sensor signals stopped.
bit5: Spindle rotation speed clamp
Specify whether to clamp the rotation speed in constant surface speed mode when the
spindle rotation clamp command is issued.
0: Clamps the rotation regardless of the constant surface speed mode.
1: Clamps the rotation only in constant surface speed mode.
bit7: Switch the range of tool life data to be input
Set up the range of tool life data to be input or compared.
0: Inputs or compares all of the data output.
1: Inputs or compares part of the data output
1) Tool life management I data to be input or compared tool number (D), lifetime (E), life
count (F), and auxiliary data (B).
2) Tool life management II data to be input or compared Group number (G), method (M), life
(E/F), tool number (D), and compensation number (H)
【#1228】 aux12
bit1: Switch "offset and parameter" screen
Select to switch the "offset and parameter" screen to the parameter screen.
0: Display the "offset and parameter" screen.
1: Display the "parameter" screen.
bit2: Switch data protection in data transmission mode
Select the range of data protection in data transmission mode.
0: Enable the protection for both send and receive data.
1: Enable the protection for receive data only.
bit4: Select operation error or stop code
Select operation error or stop code to provide for both block start and cutting start interlocks.
0: Operation error
1: Stop code
bit5: Select constant surface speed coordinates
Select the constant surface speed coordinate.
0: Workpiece coordinate
1: Absolute value coordinate
bit6: Switch relative values displayed
Select whether to preset the relative coordinates with workpiece coordinate preset (G92.1)
or counter preset (G92).
0: Preset the relative coordinates.
1: Not preset the relative coordinates.
bit7: Protection with manual value command
Select whether to protect a manual value command.
0: Not protect. (Conventional specification)
1: Protect.