Specifications
II Parameters
Base Specifications Parameters
II - 67
【#1213(PR)】 proaxy Side 1 of inclination angle (for L system only)
Set the length within the orthogonal coordinate of the inclined axis, a side of the triangle
formed with the inclination angle.
---Setting range---
-9999.999 to 9999.999
【#1214(PR)】 macaxy Side 2 of inclination angle (for L system only)
Set the actual length of the base axis corresponding to the inclined axis, a side of the
triangle formed with the inclination angle.
---Setting range---
-9999.999 to 9999.999
【#1215(PR)】 macaxx Side 3 of inclination angle (for L system only)
Set the actual length of the inclined axis, a side of the triangle formed with the inclination
angle.
---Setting range---
-9999.999 to 9999.999
【#1216】 extdcc External deceleration level
Set the upper limit value of the feedrate when the external deceleration signals are enabled.
---Setting range---
1 to 999999 (mm/min)
【#1217】 aux01
Not used. Set to "0".
【#1218】 aux02
bit3: Parameter input/output format
Select the parameter input/output format.
0: Type I
1: Type II (related to "#1218 aux02/bit5")
bit4: External workpiece coordinate offset tool number selection
Select the R register that contains the tool number used for automatic calculation when
measuring the coordinate offset of an external workpiece.
0: Follow the setting of "#1130 set_t".
1: Use the tool number indicated by user PLC.
bit5: Parameter I/O II spindle specification address
Select the spindle specification address of parameter I/O type II.
0: C
1: T
This parameter is also applied to the spindle specification address for input and verification.
(Note) This parameter is valid only for parameter I/O type II (when "#1218 aux02/bit3" is set
to "1").
bit6: Set No. valid when program input
Select which program No. is applied when inputting programs in "#1 MAIN PROGRAM" on
Data I/O screen.
0: The No. in the input data
1: The No. set in the data setting area
bit7: Input by program overwrite
(1) Select the operation when the program to be input in "#1 MAIN PROGRAM" on Data I/O
screen, has already been registered.
0: An operation error (E65) occurs.
1: Input by overwrite.
(2) Select the operation in the high-speed program server mode, when the name of the file
to be transmitted with (IC -> host) transmission already exists in the host.
0: Prohibit overwrite
1: Enable overwrite