Specifications
II Parameters
Base Specifications Parameters
II - 63
【#1188】 spd_F4 F1 digit feedrate F4
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F4 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be
increased/decreased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
【#1189】 spd_F5 F1 digit feedrate F5
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F5 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be
increased/decreased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
【#1190(PR)】 s_xcnt Validate inclined axis control (for L system only)
Select whether to enable or disable inclined axis control.
0: Disable inclined axis control
1: Enable inclined axis control
【#1191(PR)】 s_angl Inclination angle (for L system only)
Set the inclination angle (θ).
(Note) When set to "0", the angle determined by three-side setting will be applied.
---Setting range---
-80.000 to 80.000 (°)
【#1192(PR)】 s_zrmv Compensation at reference position return (for L system only)
Select whether to perform compensation for the base axis corresponding to the inclined axis
at reference position return.
0: Perform compensation
1: Not perform compensation
【#1193】 inpos Deceleration check method 1/ Validate in-position check
The definitions are changed with the setting of "#1306 InpsTyp Deceleration check
specification type".
<When Deceleration check method 1 is selected>
Select the deceleration check method for G0.
0: Command deceleration check
1: In-position check
<When Deceleration check method 2 is selected>
Select the deceleration confirmation method for the positioning or cutting command.
0: G0, G1+G9 Command deceleration check
1: G0, G1+G9 In-position check
【#1194】 H_acdc Time constant 0 for handle feed
Select the time constant for manual handle feed.
0: Use time constant for G01
1: Time constant 0 (step)
【#1195】 Mmac Macro call for M command
Select whether to enable or disable M command macro call of user macro.
0: Disable
1: Enable
【#1196】 Smac Macro call for S command
Select whether to enable or disable S command macro call of user macro.
0: Disable
1: Enable
【#1197】 Tmac Macro call for T command
Select whether to enable or disable T command macro call of user macro.
0: Disable
1: Enable
【#1198】 M2mac Macro call with 2nd miscellaneous code
Select whether to enable or disable 2nd miscellaneous command macro call of user macro.
0: Disable
1: Enable
【#1199】 Sselect Select initial spindle control
Select the initial condition of spindle control after power is turned ON.
0: 1st spindle control mode (G43.1)
1: Selected spindle control mode (G44.1)
2: All spindle simultaneously control mode (G47.1)
(Note) Spindle No. when G44.1 is commanded is selected with “#1534 SnG44.1”.